SSV 05

5.4. Trouble-shooting

 

Problem

Remedy

The unit is not conveying

 

and is not active

a, b, g, h

The unit is not conveying;

 

the compressed-air valve is switched

 

when the device is switched on

c, f

The unit is not conveying,

 

the compressed air is flowing audibly

c, d, e, f, i, j, k

The unit is overfilled

g, l, m

The unit is not filled properly

c, d, e, f, i, j, k, l

Test steps

 

a)Check whether the unit is switched on.

b)Check whether the mains connector is connected and mains voltage is present.

c)Check whether sufficient compressed air is available.

d)Check whether the injector tube is inserted in the material.

e)Check whether the compressed-air hose is properly connected to the injector tube.

f)Check whether the compressed-air hose is properly connected to the maintenance unit.

g)Check whether the level probe is properly adjusted.

h)Check whether the cable of the level probe is properly connected.

i)Check whether the filter is clogged.

j)Check whether the sieve is clogged.

k)Check whether the conveyor hose is properly connected.

l)Check whether the compressed-air supply is properly adjusted.