Sterling STT 500 manual STT 3.5.2. Entering dryer values, Start-up, Regeneration Heater Act

Models: STT 500

1 87
Download 87 pages 16.91 Kb
Page 24
Image 24
STT 500

STT 500

3.5.2. Entering dryer values

Select ”Dryer”.

Acknowledge with the ENTER-key.

or

Press the ”F3”-key.

Regeneration Heater Act.

The regenerated heat temperature will be displayed.

Used air Act.

The current temperature of the used air will be displayed.

Press the “â” key.

&

If the unit operates with “Dew point dependent regeneration switch” (op- tional):

Dew point max.

Enter the maximum permissible (worst allowed) dew point temperature (-35 to 28 °C) (-31 to 82.4°F)..

Acknowledge with the ENTER-key.

Dew point Act.

The current dew point temperature will be displayed.

&

If there is a cable break “+0 °C” (32°F) is displayed.

Press the “â” key.

SM2-620

Start-up 3-9

Page 24
Image 24