B.Place the FREEZING CYLINDER
switch in the ON position and push the CLEAN switch to rotate the auger. Allow the mix to agitate in the freezer barrel until the mix has become a liquid, about 5 minutes.
C.Drain the liquid mix by opening the spigot. A bucket or container should be placed under the spigot to catch the liquid mix (Fig. 17).
D.Place the Freezing Cylinder
Figure 17. Draining Mix
3.7 CLEANING THE FREEZER
NOTE
The frequency of cleaning the freezer and freezer parts must comply with state and local health regulations.
After the mix has been removed from the freezer, the freezer must be cleaned. To clean the freezer, refer to the following steps:
A.Close the spigot and fill the hopper with 2 gallons (7.5 liters) of cold tap water.
B.Place the FREEZING CYLINDER
C.Allow the water to agitate for approximately five minutes.
NOTE
If freezer is left in CLEAN for more than 30 minutes, it will go into error. Turn the FREEZING CYLINDER
D.Open the spigot to drain the water. Remember to place a bucket or container under the spigot to catch the water. When the water has drained, turn the FREEZING CYLINDER
CAUTION
Hazardous Moving Parts
Revolving blender agitator shaft can grab and cause injury. Remove watches and jewelry prior to operating blender. Keep hands and clothing away from revolving agitator. The Power switch must be placed in the OFF position for cleaning and when not in use.
E. Fill a tall cup with clean 110°F (43°C) water. Press the low speed on the blender activation switch and allow agitator to run for 10 to 15 seconds (See Figure 18).
Figure 18. Cleaning Agitator Shaft
F.Repeat steps A through E using a mild detergent solution.
3.8 DISASSEMBLY OF FREEZER PARTS
CAUTION
Hazardous Moving Parts
Revolving auger shaft can grab and cause injury.
Place the FREEZING CYLINDER
switch in the OFF position before disassembling for cleaning or servicing.
Inspection for worn or broken parts should be made at every disassembly of the freezer for cleaning or other purposes. All worn or broken parts should be replaced to ensure safety to both the operator and the customer and to maintain good freezer performance and a quality product. Two normal wear areas are the auger flights and front auger support bushing (Fig. 19). Frequency of cleaning must comply with the state and local health regulations.
12