SECTION 3
INITIAL SETUP AND OPERATION
3.1OPERATOR'SSAFETYPRECAUTIONS
SAFE OPERATION IS NO ACCIDENT; Observe these rules:
A.Know the freezer. Read and understand the Operating Instructions.
B.Notice all warning labels on the freezer.
C.Wear proper clothing. Avoid loose fitting garments, and remove watches, rings or jewelry which could cause a serious accident.
D.Maintain a clean work area. Avoid accidents by cleaning up the area and keeping it clean.
E.Stay alert at all times. Know which switch, push button or control you are about to use and what effect it is going to have.
F.Disconnect electrical cord for maintenance. Never attempt to repair or perform maintenance on the freezer until the main electrical power has been disconnected.
G.Do not operate under unsafe operating condi tions. Never operate the freezer if unusual or exces- sive noise or vibration occurs.
3.2OPERATING CONTROLS AND INDICATORS Before operating the freezer, it is required that the operator know the function of each operating control. Refer to Figure 8 for the location of the operating controls on the freezer.
A.Clean OFF ON Switch
The clean off on switch is a three position switch. In the clean position only the drive and condenser fan will run. In the ON position the drive and condenser fan and compressor will run until the proper consis- tency is reached, then the compressor will stop and the drive and condenser fan will continue to run.
B.Mix Low Light
The mix low light will illuminate when the liquid level in the hopper is less than 2".
C.Standby Serve Switch
The standby switch is a two position switch. In the standby position mix temperature will be maintained between 32° and 40°F. In the serve position the product temperature in the barrel will be determined by product consistency.
D.Lights Off On Switch
The lights Off On Switch is a two position switch. When the switch is in the ON position the lights will illuminate, when the switch is in the off position the lights will be OFF.
Figure 5. Controls
E.High Pressure Cut Out Switch
The high pressure cut out switch is located under the right side frame about halfway back. Push up to reset.
Figure 6. Disassembling Freezer
3.3. DISASSEMBLY OF FREEZER PARTS
CAUTION
PLACE THE CLEAN OFF ON SWITCH IN THE OFF POSITION BEFORE DISASSEMBLING FOR CLEANING OR SERVICING.
Inspection for worn or broken parts should be made at every disassembly of the freezer for cleaning or other purposes. All worn or broken parts should be replaced to ensure safety to both the operator and the customer and to maintain good freezer performance and a quality prod- uct. Frequency of cleaning must comply with the local health regulations.