Stovax 7118 Removal Of The Log Guard, Fitting And Removal Of Baffle, MAINTENANCE and SERVICING

Models: 7118

1 16
Download 16 pages 35.82 Kb
Page 10
Image 10
5.REMOVAL OF THE LOG GUARD

MAINTENANCE and SERVICING

4.15This is a list of the maintenance products you may need to use

Task

Product name

Stovax Code

Number

 

 

Glass cleaning

Stove glass cleaner 500ml

4111

 

(wipe on)

 

 

 

 

 

 

Stove glass cleaner

4130

 

(spray on)

 

 

 

 

 

Preventing build-up

Protector (15 sachets)

7002

of creosote in flue

Protector (1kg tub)

7025

 

 

 

Sealing flue

Fire Cement (500g tub)

2020

pipe joints

Fire Cement (600g cartridge)

2021

 

 

 

Re-painting

Thermolac Black

2019

 

(400ml aerosol)

 

 

 

 

 

 

Thermolac Black

2057

 

(9200ml brush-on)

 

 

Cleaning matt

Colloidal black (85ml)

7000

black stoves

 

 

 

 

 

 

Protecting your

Heat resistant leather gloves

4008

hands

 

 

 

 

 

 

Door sealing rope

14mm Black rope seal

5000

 

(handy pack)

 

 

 

 

 

 

14mm Black rope seal

4670

 

(25m reel)

 

 

Glass sealing tape

3mm Black rope seal

4975

 

(handy pack)

 

 

 

 

 

 

3mm Black rope seal

4974

 

(25m reel)

 

 

 

 

 

Fixing rope seal

Thermic seal glue

5037

 

(50ml bottle)

 

 

 

 

 

Ash Clean

Vaccuum Cleaner Attachment

2091

 

 

 

4.16These products, all available from your local Stovax dealer, along with regular maintenance and use of correct fuels, will help you to keep your stove in the best condition.

4.17If you require more information about Stovax group products, visit ouor website www.stovax.com.

4.18When using the stove for the first time again it is best to burn the fire at a low output for the first day of use. This will allow the new seals to settle and all new fixing glues and paint to fully cure.

4.19During this time, the stove may give off some unpleasnt odours, and we recommend that you keep the room well ventialted during thsi period to avoid a build-up of fumes.

4.20If you require help, your local Stovax dealer will be able to carry out all of your service and maintenance requirements for a reasonable cost.

5.REMOVAL OF THE LOG GUARD

5.1Remove the log guard by lifting clear of the supporting brackets and rotating to clear the sides of the door opening. The stove should not be used without the log guard in position.

6.FITTING AND REMOVAL OF BAFFLE

6.1To maintain efficient combustion the stove is fitted with a baffle in the top of the firebox.

6.2Allow the stove to cool fully before removing the baffle system.

6.3To remove the baffle, first remove the log guard from the stove to give access to the firebox.

6.4Remove the baffle by lifting the front edge to clear the support bars, then pull the baffle forward to disengage the rear edge from the location above air inlet holes. Rotate the baffle to remove from the firebox through the door opening.

Support Pin

PR7214

 

6.5The replacement of the system is the reverse of the previous operations, ensuring it is replaced the correct way around.

Front

PR7076

10

Page 10
Image 10
Stovax 7118 manual Removal Of The Log Guard, Fitting And Removal Of Baffle, MAINTENANCE and SERVICING