1.1

These instructions apply to Stockton 3/4/5/6/7 when fitted

 

with a Smoke Control kit.

 

 

NOTE: These appliances have been independently tested to

 

PD6434 and approved by DEFRA as an exempted appliance

 

allowing it to burn wood in Smoke Control areas when fitted

 

with a Smoke Control kit.

 

 

 

 

Product

Appliance

Smoke control kit

 

Code

 

Part No.

 

7125

Stockton Inset Convector

ST5SCKIT

1.2

To meet the Smoke Control requirement this appliance must

 

be operated correctly in order to minimise the amount of

 

smoke produced.

 

1.3

Burn only dry wood

 

1.4

These instructions must be left with the user and kept with

 

the original instructions they superseded.

2. RECOMMENDED FUELS

2.1 Wood Logs:

• Burn only seasoned timber with a moisture content of less than 20%

Appliance

Maximum Length

Maximum Diameter

 

 

 

Stockton Inset

325mm

100mm

Convector

 

 

 

 

 

• Dry cut wood for 12 to 18 months before use

Poor quality timber:

Causes low combustion efficiency

Produces harmful condensation

Reduces effectiveness of the airwash and life of the appliance

Do not burn construction timber, painted, impregnated / treated wood, manufactured board products or pallet wood.

3.Lighting the Appliance

3.1For best results:

Set air controls, See below.

Stockton 7 Air Wash: Fully Open Stockton 8

Primary Air: 25% Open

Stockton 7

 

 

 

Stockton 8

Secondary Air:

Fully Open

Place firelighters or paper and dry kindling wood on the grate

Light the paper or firelighters, See Diagram 2

Leave the door slightly open as the fire establishes and the glass warms to avoid the build-up of condensation

Add larger pieces of wood

Too many logs may smother the fire.

Do not load fuel above the log guard and the secondary combustion inlets at the back of the firebox.

See Diagram 3

2