6.Grasp the starter grip (Figure 11) and slowly pull it out.The resistance becomes the hardest at a certain position, corre- spondingtothecompressionpoint.Pullthestartergripbriskly and smoothly for starting.

Figure 11. Starter Grip

7.If the engine has started, slowly return the choke lever (Figure 12 ) to the “CLOSED“ position. If the engine has not started repeat steps 1 through 6.

CAUTION :

ALWAYS run engine at full speed while pumping.

Stopping The Engine

Normal Shutdown

1.Movethethrottlelever tothe“IDLE“position (Figure14)and run the engine for three minutes at low speed.

Figure 14.Throttle Lever (Idle)

2.Aftertheenginecools,turntheengineON/OFFswitchtothe “OFF” position (Figure 15).

Figure 12. Choke Lever (Closed)

8.Before the pump is placed into operation, run the engine for severalminutes. Checkfor fuelleaks,andnoisesthatwould associate with a lose component.

9.To begin pumping, place the throttle lever (Figure 13) in the "RUN" position.

Figure 13. Throttle Lever (Run)

Figure 15. Engine ON/OFF Switch (OFF)

3.Place the fuel shut-off lever (Figure 16) in the “OFF“ position.

Figure 16. Fuel Valve Lever (OFF)

Emergency Showdown

1.Move the throttle lever quickly to the “IDLE“ position, and place the engine ON/OFF switch in the “OFF“ position.