MS20H/MS20E MIXER — INITIAL START-UP

This section is intended to assist the operator with the initial start-up of the MS-20H (gasoline) or MS20E (electric) mixer.It is extremely important that this section be read carefully before attempting to use the mixer in the field.

DO NOT use your mixer until this section is thoroughly understood.

CAUTION:

Failure to understand the operation of the MS20H/MS20E mixers could result in severe damage to the mixer or personal injury.

See Figure 4 (Page 17) for the location of any control referenced in this manual.

Starting (gasoline only)

The following steps outline the procedure for starting the engine. Depending on the type of engine employed in the mixer the steps may vary slightly. If your mixer has an electric motor disregard this section.

1.Move the fuel shut-off lever (Figure 12) to the ON position.

2.To start a cold engine, move the choke lever (Figure 13) to the CLOSED position.

Figure 13. Choke Lever

3.Move the throttle lever (Figure 14) away from the slow position, about 1/3 of the way toward the fast position.

Figure 14. Throttle Lever

Figure 12. Fuel Shut-OFF Lever

MQ STOW MS20H/MS20E MIXER — PARTS & OPERATION MANUAL — REV. #3 (08/10/06) — PAGE 25

Page 25
Image 25