Studer Innotec AJ SERIES manuel dutilisation Safety, Failure Consequence Solution

Models: AJ SERIES

1 24
Download 24 pages 2.31 Kb
Page 6
Image 6

STUDER INNOTEC

AJ

Safety

The inverter is electronically protected. But protection against polarity inversions of the battery occurs with an internal fuse, except for AJ 2100-12 inverter, which has no fuse. The following table will show you the different failures and their consequences.

FAILURE

CONSEQUENCE

SOLUTION

Low battery voltage

Inverter momentarily

Automatic restart when the

Voltage < 1.8V/cell

stopped, the green

battery voltage rises

 

indicator blinks.

 

Deep discharged battery

Inverter stopped

Inverter should be manually

(voltage <1,5V/cell)

 

restarted when the battery

 

 

as reach 2V/cell

Overheating

Inverter momentarily

Automatic restart when the

 

stopped, the green

temperature reaches the

 

indicator blinks.

normal range.

Battery over voltage

Inverter stopped.

Wait until the battery voltage

 

 

reaches the correct level.

 

 

Push the ON/OFF switch to

 

 

reactivate the inverter

 

 

 

Short circuit in the outlet

Inverter stopped.

Eliminate the short circuit.

 

 

Push the ON/OFF switch to

 

 

reactivate the inverter.

Overload

Inverter stopped.

Use the inverter only in the

 

 

range of its nominal power.

 

 

Regular use in overload

 

 

power diminished the

 

 

lifetime of the inverter.

 

 

Push the ON/OFF switch to

 

 

reactivate the inverter.

Inversion of the battery

Internal fuse broken down

Back to manufacturer for

polarity

 

testing