Sub-Zero 542 manual Hinge Adjustment, Installation Check List, Ive the customer Warranty packet

Models: 542

1 12
Download 12 pages 17.15 Kb
Page 9
Image 9

i'"'ISTALLATION" ',,4STRUCTIONS

2)Using the Loctite on the screws, install all 3 Chicago Screw Posts.

3)Inspect the units for level again.

4)Drill three (3) 3t16" holes (per specs in Figure 24) through both outer trims.

5)Using a 1/8" drill bit, drill into the cabinetry for a pilot hole.

6)Install all six (6) Seres to the cabinetry.

Instructions for fastening Models 501R, 501F, 550, 511, 561, 532, 542 and 590 to cabinetry (see Figure 25):

17t/a _

1)Drill three (3) 3h6" holes (per specs in Figure 25) through both outer trims.

2)Drill a Vs" pilot hole into the cabinetry.

?''qstallall six (6) Sems.

HINGE

ADJUSTMENT

Step 16

Ifthe doors are out of adjustment, the top or bottom hinge may be adjusted by removing and discarding the two small shipping screws. See Figure 26. The top door hinges can be adjusted left to

right and in or out by loosen- ing the three allen head screws. The bottom door

hinge is equipped with two adjustment allen head screws. See Figure 27.

For adjustment, use a 118" allen wrench to loosen screws

(models 550 and 511 ex- cluded). This allows the door to move left to right or in and out.

NOTE: On Models 532, 542, 561, 501R, 501F and 590 the doors open to 130 ° .

An optional door stop kit (4-20-089-0), which allows a door opening of approxi- mately 90 ° is available. Contact your distributor.

Figure 26

Figure 27

INSTALLATION

CHECK LIST

The importance of the installa- tion of your Sub-Zero cannot be overemphasized. The

proper installation of your unit is the responsibility of the selling dealer or instal-

ler. The following check list should be completed by the installerto insure no part of the installation has been over- looked. Any questions or problems pertaining to the installation should be directed to the selling dealer.

[] Is unit operating? If not, is unit plugged in? Is refrigerator/ freezer control on?

[] Is packing material removed? (Step 6)

[] Is water supply line con- nected to compression fitting? (Step 8)

IAWARNING l

Disconnect power to unit before checking wiring connections.

[] Is blocking completed? (Step 8)

[] Is unit leveled properly on a solid floor?. (Step 10)

[] Is blocking necessary? (Step 8)

[] Is drain pan installed properly? (Step 11)

[] Is toe plate installed? (Step 11)

[] Isgrille screw back in position? (Step 12)

[] Are panels installed correctly? (Step 14)

[] Are doors adjusted? (Step 16)

[] Does the customer under- stand the unit'soperation?

[] Isthe icemaker switch turned on? (Models 590, 532, 542 and 561).

(_ive the customer the

warranty packet.

9

Page 9
Image 9
Sub-Zero 542 manual Hinge Adjustment, Installation Check List, Disconnect power to unit before checking wiring connections