Planning Information

36" (914) Framed Electric Cooktop

M O D E L C T 3 6 E

I N T E G R A T E D M O D U L E S —

M U L T I P L E U N I T I N S T A L L A T I O N

With Wolf's integrated modules, you have the ultimate in customization. You can create your own design by mixing and matching the various components within this system. And when you couple these modules with other cooktops within the Wolf inventory you and your client will truly understand freedom of choice.

Some Wolf integrated modules can be installed together or with a 30" (762) or 36" (914) cooktop. When multiple units are installed side by side, the cut-out dimensions that are shown in the illustration are derived by adding 11/4" (32) additional space for each additional unit, to give you your total cut-out width. Refer to the illus- tration below for countertop cut-out dimensions for installation of multiple cooktops.

IMPORTANT NOTE: Refer to the pages for each specific integrated module for installation limitations.

IMPORTANT NOTE: Where multiple cooktops and/or modules are installed side by side, each unit must have its own separate recommended electrical circuit.

When two or more cooktops or modules are installed together, an integrated module filler strip is recommended. Contact your Wolf dealer for information on this accessory component.

For electrical requirements, additional specifica- tions and installation limitations, refer to the Integrated Modules pages on our website, wolfappliance.com.

IMPORTANT NOTE: Review specific installation instructions for product to product capabilities.

593/4" (1518) FOUR MODULES WIDTH OR

591/2" (1511) 30" COOKTOP AND TWO MODULES OR

501/4" (1276) 36" COOKTOP AND ONE MODULE

441/2" (1130) THREE MODULES WIDTH OR

441/4" (1124) 30" COOKTOP AND ONE MODULE

291/4" (743)

TWO MODULES WIDTH

21/2"min

(64)

14"

(356)

CUT-OUT

WIDTH

191/4"

(489) CUT-OUT DEPTH

FRONT OF COUNTERTOP

Countertop cut-out dimensions for installation of multiple cooktop units.

Dimensions in parentheses are in

 

millimeters unless otherwise specified.

7

Page 7
Image 7
Sub-Zero CT36E dimensions L T I P L E U N I T Installation, 593/4 1518 Four Modules Width or