GAS INSTRUCTIONS
CHECK FOR GAS LEAKS
After a period of nonuse, we recommend that you perform the following maintenance procedures for your safety.
WARNING: Check the hose before each use of the grill for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the grill. Replace using only Summit® authorized replacement hose. Contact the Summit®
•Inspect the burners for correct fl ame pattern. Clean if necessary, following the procedures outlined in the “General Maintenance” section of this manual.
•Check all gas fi ttings for leaks.
DANGER
Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, which can cause serious bodily injury or death and damage to property.
WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.
Note - All
fittings for leaks before using your Weber Gas Barbecue. Shipping and handling may loosen or damage a gas fi tting.
WARNING: Perform these leak checks even if your barbecue was dealer or store assembled.
You will need: a soap and water solution, and a rag or brush to apply it.
Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.
Make sure side burner is OFF.
To perform leak checks: open cylinder valve by turning the cylinder valve
WARNING: Do not ignite burners when leak checking. Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if
a bubble grows, there is a leak. Check:
1)Gas
2)
WARNING: If there is a leak at connection (1), retighten the fitting with a wrench and recheck for leaks with soap and water solution.
If a leak persists after
Customer Service 1-800-446-1071.
Check:
3)“T”
4)The
WARNING: If there is a leak at connections (2,3, or 4), turn OFF the gas. DO NOT OPERATE THE GRILL.
Contact Customer Service 1-800-446-1071.
When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.
(1)
Side View
(2)
Side View
(3)
(4)
10