4

GAS INSTRUCTIONS

LOCATING YOUR BUILT-IN SIDE BURNER

When determining a suitable location for your Built-In Side Burner installation, give attention to concerns such as exposure to wind, proximity to traffi c paths, and keeping any gas supply lines as short as possible. Never locate the Summit® Built-In Side Burner in a garage, breezeway, shed, under an unprotected overhang, or other enclosed area. Locate the Side Burner and structure so there is enough room to safely evacuate the area in case of a fi re.

CLEARANCE FROM COMBUSTIBLE SURFACES OR STRUCTURES

WARNING: Clearance from the outside walls of the sides and back of the LP Tank Cabinet must be a minimum of 24 inches (61 cm) any surface. Refer to “Typical Gas Supply Installation” before starting installation.

WARNING: The structure, “island” counter tops and adjacent work areas for the LP Tank Cabinet installation must be built from noncombustible materials only.

NOTE: If you have questions on what materials are considered noncombustible, contact

A B

1

B

C

2

B A

you local building supplier or fire department.

 

SIDE BURNER LOCATION

A

Any Surface

B

24” (61 cm) From Any Surface

C

Side Burner

1

24” ( 61 cm) Minimum Lid Clearance

2

Note: For a countertop treatment: Recommended 3/4” (19 mm)

overhang. Notch front edge for frame to fully slide in.

 

 

 

BUILT-IN SRUCTURE CUTOUT DIMENSIONS

WARNING: All counter top finished surfaces must be

All dimensions are to fi nished surfaces.

constructed of a noncombustible material.

 

A

B

C

SIDE BURNER

Cut out Dimensions

Tolerances

10

1/2”

(26.7 cm)

+ 1/4”

- 1/4” (6.35mm)

3

3/4”

(9.5 cm)

+ 1/4”

- 1/4” (6.35mm)

16

1/4”

(41.3 cm)

+ 1/4”

- 1/4” (6.35mm)

 

 

 

 

 

WWW.WEBER.COM®

Page 4
Image 4
Summit 89795 manual GAS Instructions, Side Burner Location, Locating Your BUILT-IN Side Burner