Trouble-Shooting Guide

During the service of your appliance, you can come across some troubles that in most cases result from improper handling of the appliance that can easily be eliminated.

The Appliance Fails to Operate After Connecting to the Power Supply

Check the supply in the outlet socket and make sure the appliance is switched on (thermostat in the operating position).

Continuous Operation of the Refrigerating System

The door was frequently opened or it was left open too long.

The door is not properly closed (the door may sag; the gasket may be polluted or damaged).

Perhaps you have overloaded the appliance with fresh foods.

The reason may be inadequate ventilation of the compressor and condenser (assures adequate air circulation and wipe off the condenser).

Ice Formation on the Inner Rear Wall

As long as the defrost water runs to the channel and through the opening to the drain pan on the compressor, automatic defrosting of the appliance is assured. In case the ice formation on the inner back wall is increased (1/8”), ice should be manually defrosted.

Set the thermostat knob to 0 (off) position and leave the door open. Never use electric devices for defrosting and do not scrape the ice or frost layer with sharp objects. After completed defrosting, turn the knob to desired position and close the refrigerator door.

The cause of increased ice formation may be one of the following reasons:

-The door does not seal well (clean the gasket if it is contaminated, or replace it if it is damaged).

-The door was frequently opened or it was left opened for too long.

-The food stored in the refrigerator was warm.

-The food or dish is touching the inner back wall.

Water is Leaking from the Refrigerator

In case the discharged water outlet is clogged, the defrost water drips over the channel, or water leaks from the refrigerator just clean the clogged opening with a plastic straw. Manually defrost the increased ice layer.

Instructions for Use

Page 7
Image 7
Summit FFAR-10 instruction manual Trouble-Shooting Guide, Continuous Operation of the Refrigerating System