18 SunFDDI/P1.0 Adapter User’s GuideMay 1997
3
If VolumeManager (vold) is not running on your machine, unmount the
CD-ROM before you eject and remove the directory that you created:
3. Reboot your machine.

To Check the Installation

1. Use netstat(1M) to check for SunFDDI/P interfaces.
2. Use ifconfig(1M) to check the current state of the SunFDDI/P
interfaces.
3. Use ping(1M) to verify that you can send and receive data across the
FDDI connection.
If your SunFDDI/P station is attached to an active FDDI network, try to
access a remote station.
#/usr/sbin/umount /cdrom/sunfddip_1_0
#eject cdrom
#rmdir /cdrom/sunfddip_1_0
%/usr/bin/netstat -i
Name Mtu Net/Dest Address Ipkts Ierrs Opkts Oerrs Collis
Queue
lo0 8232 loopback localhost 21 0 21 0 0 0
le0 1500 our-lan hysop 2146 0 950 1 13 0
pf0 4352 our-fddi hysop-pf 1086 0 907 0 0 0
%/usr/sbin/ifconfig pf0
pf0:flags=863<UP,BROADCAST,NOTRAILERS,RUNNING,MULTICAST> mtu 4352
inet <host_address> netmask <netmask> broadcast <ip_address>
ether <mac_address>
%/usr/sbin/ping hemlock-pf
hemlock-pf is alive
SunFDDIInterface
pf<inst>---->