Sun Microsystems T3 manual Host Multipathing Management Software, Lun

Models: T3

1 88
Download 88 pages 44.06 Kb
Page 42
Image 42

Host Multipathing Management Software

While Sun StorEdge T3 and T3+ arrays are redundant devices that automatically reconfigure whenever a failure occurs on any internal component, a host-based solution is needed for a redundant data path. Supported multipathing solutions include:

The DMP feature in VERITAS Volume Manager

Sun Enterprise Server Alternate Pathing software

Sun StorEdge Traffic Manager software

During normal operation, I/O moves on the host channel connected to the controller that owns the LUNs. This path is a primary path. During failover operation, the multipathing software directs all I/O to the alternate channel’s controller. This path is the failover path.

When a controller in the master controller unit fails, the alternate master controller unit becomes the master. When the failed controller is repaired, the new controller immediately boots, goes online and becomes the alternate master controller unit. The former alternate master controller unit remains the master controller unit.

Note – The multipathing software solution must be installed on the application host to achieve a fully redundant configuration.

FIGURE 4-3shows a failover configuration.

LUN 1

 

 

 

Alternate

 

Ethernet

 

master

 

connection

 

controller

 

 

 

unit

 

Application host

 

 

Interconnect

HBA

Primary LUN 1

cables

 

 

 

Failover LUN 0

 

 

 

LUN 0

 

 

Primary LUN 0

Master

 

 

controller

 

HBA

Failover LUN 1

unit

 

 

 

FC-AL connection

 

 

 

Ethernet

 

 

 

connection

 

Ethernet port

 

 

LAN

 

 

 

 

 

Management host

FIGURE 4-3

Failover Configuration

 

 

30 Sun StorEdge T3 and T3+ Array Configuration Guide • August 2001