![](/images/new-backgrounds/1186263/18626383x1.webp)
Host Multipathing Management Software
While Sun StorEdge T3 and T3+ arrays are redundant devices that automatically reconfigure whenever a failure occurs on any internal component, a
■The DMP feature in VERITAS Volume Manager
■Sun Enterprise Server Alternate Pathing software
■Sun StorEdge Traffic Manager software
During normal operation, I/O moves on the host channel connected to the controller that owns the LUNs. This path is a primary path. During failover operation, the multipathing software directs all I/O to the alternate channel’s controller. This path is the failover path.
When a controller in the master controller unit fails, the alternate master controller unit becomes the master. When the failed controller is repaired, the new controller immediately boots, goes online and becomes the alternate master controller unit. The former alternate master controller unit remains the master controller unit.
Note – The multipathing software solution must be installed on the application host to achieve a fully redundant configuration.
FIGURE 4-3 shows a failover configuration.
LUN 1 |
|
|
|
Alternate |
| Ethernet |
|
master |
| connection |
|
controller |
|
|
|
unit |
| Application host | |
|
| ||
Interconnect | HBA | Primary LUN 1 | |
cables |
| ||
|
| Failover LUN 0 | |
|
|
| |
LUN 0 |
|
| Primary LUN 0 |
Master |
|
| |
controller |
| HBA | Failover LUN 1 |
unit |
|
|
|
|
| ||
| Ethernet |
|
|
| connection |
| Ethernet port |
|
| LAN | |
|
|
| |
|
| Management host | |
FIGURE | Failover Configuration |
|
|