Chapter 4: BIOS
4-15
Terminal Type 
Selects the type of the target terminal: ANSI, VT100 and VT-UTF8.
VT-UTF8 Combo Key Support 
Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/
VT100 terminals.  
Sredir Memory Display Delay 
Use this setting to set the delay in seconds to display memory information.  Op-
tions are No Delay, 1 sec, 2 secs and 4 secs. 
  System Health Monitor
CPU Overheat Temperature
Use the "+" and "-" keys to set the CPU temperature threshold to between 65o 
and 90o C.  When this threshold is exceeded, the overheat LED on the chas-
sis will light up and an alarm will sound.  The LED and alarm will turn off once 
the CPU temperature has dropped to 5 degrees below the threshold set.  The 
default setting is 72o C.
Other items in the submenu are systems monitor displays for the following in-
formation:  CPU1 Temperature, CPU2 Temperature, CPU3 Temperature, CPU4 
Temperature, (for 4U systems), System Temperature, CPU1 Vcore, CPU2 Vcore, 
CPU3 Vcore, CPU4 Vcore (for 4U systems), 3.3V Vcc, +5Vin, +12Vin, 5V standby 
and battery voltage.
  System Fan Monitor 
Fan Speed Control
This feature allows the user to determine how the system will control the speed of 
the onboard fans.   Select "Workstation" if your system is used as a Workstation.  
Select "Server" if your system  is used as a Server. Select "Disable" to disable  
the fan speed control function to allow the onboard fans to continuously run at 
full speed (12V).  The options are 1) Disabled (Full Speed)  2) Optimized for 
Server and  3) Optimized for Workstation.
FAN1 Speed through FAN9 Speed
The speeds of the onboard fans (in rpm) are displayed here.