Canopy

Side View

Figure 13

OPTIONAL EQUIPMENT

Blower Kits

The FBK-100 Blower Kits are used when

awall-mounted ON/OFF blower switch is desired, and the FBK-200 Blower Kits are used when a wall-mounted variable speed blower control (rheostat) is desired. A Junction Box / Electrical Kit is also required to install these kits (purchased separately - see Page 15).

The blower is installed beneath the firebox. Room air is drawn in through the side slots of the fireplace, heated as it passes across the firebox, and discharged through the upper area of the firebox opening.

The installation instructions for installing these blower kits are on Pages 12 through 14. Also see the installation instructions provided with the blower kits (Form #750,028M). For electrical requirements, refer to Figures 14, 15 & 16.

If the blower kit is to be installed at the time of installation or at a later date, the main power supply must be installed at the time of instal- lation. This will require that the electrical connections must be made BEFORE the firebox is framed and enclosed in the finished walls. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply and connect to electrical receptacle wires and wall switch or rheostat.

12

IMPORTANT

TheGroundLead mustbeconnected to the green screw (located on the junction box). Failure to do this could result in an electrical short or shock injury.

The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the national electrical code, ANSI/NFPA 70-(latest edition). (In Canada, the current CSA C22-1 Canadian Electrical Code).

CAUTION

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service.

Blower Motor

Grounded

to Appliance

Motor Plug

Receptacle

120V

Appliance Junction Box

Note: If any of the original wire as supplied must be replaced, it must be replaced with type AWM 105 degree C - 14 gage wire.

Figure 14

NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

Top View * Junction Box

* Electrical Outlet

Blower

Bend blower mounting

 

tabs up to secure

Tie a loose knot in power

blower in place

cord to take up slack

 

*The Junction Box / Electrical Kit is not included. See Page 15 for ordering information.

Figure 15

Green-Ground White-Neutral

BlackVAC120

120V, 60HZ,

1PH BLOWER

 

 

 

 

CONTROL CIRCUIT

 

 

WIRING

 

 

* Wall-mounted ON/

 

 

 

 

OFF Blower Switch

 

 

or Variable Speed

 

 

Control Switch.

HOT SIDE OF

RECEPTACLE

Black

NEUTRAL

SIDE OF

RECEPTACLE

Junction

 

 

 

 

 

Tab

 

 

 

 

 

 

Intact

 

Box

 

 

 

 

 

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plug blower

Ground

 

 

 

 

Screw

 

 

 

 

into this

 

 

 

 

receptacle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field Wired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blower

 

 

 

 

 

 

 

 

 

Factory Wired

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

*An ON/OFF Wall Switch is used with the FBK-100 kit (field provided or sold separately - order P/N 85L87); A Variable Speed Control (provided) is used with the FBK- 200 kit. The installation of these kits also require a Junction Box / Electrical Kit, not included. See Page 15 for ordering information.

Note: If any of the original wire as supplied must be replaced, it must be replaced with type AWM 105 degree C - 14 gage wire.

Figure 16