OPERATING INSTRUCTIONS | OSRAM |
8/12/00 | SYLVANIA |
| Process Heat |
G-TEMP HEATER
065253, 066136, 070282
⇒FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.
Description
!Compact, efficient heater with integrated temperature and power controller for heating air or inert gases to 1300°F (700°C). A thermal sensor in the control box turns the heater power off if airflow is lost, or the inlet air temperature is too high. A
Specifications
MAXIMUM INLET PRESSURE |
| 2 PSI (.14 BAR) |
| |||
MAXIMUM INLET AIR TEMPERATURE |
| 100°F (38°C) |
| |||
MAXIMUM EXIT AIR TEMPERATURE |
| 1300°F (760°C) |
| |||
|
|
|
|
|
| |
MODEL | MAXIMUM |
| SUPPLY | AMP | REPLACEMENT | |
NUMBER | WATTAGE |
| VOLTAGE | RATING | ELEMENT | |
|
|
|
|
|
| NUMBER |
066136 | 1500 |
| 120 | - 60 Hz | 13 | 066137 |
065253 | 3000 |
| 230 | - 60 Hz | 15 | 065335 |
070282 | 3000 |
| 230 | - 50 Hz | 15 | 065335 |
Safety
!SHOCK HAZARD Only qualified individuals should install this heater and related controls. Follow all applicable electrical codes and use proper wiring.
131 Portsmouth Ave. Exeter, NH 03833 USA Tel: | 1 |