GreenBus II™ Wiring

Communication Circuit (24VDC, Class 2)

GreenBus IITM is a low-cost, high reliability communication means to report sensor information back to the ENCELIUM Energy Management System and to obtain optimum brightness settings for light fixtures from the system – optimized to result in minimum energy costs for any given building.

The GreenBus IITM wiring originates at an Energy Control Unit (ECU) and propagates in a daisy-chain or “T” fashion from module to module (or other compatible equipment).

GreenBus IITM uses proprietary connectors and jacks for ease of installation only.

GreenBus IITM is a proprietary standard. Connect to ENCELIUM Energy Management System only. Do not connect to other circuits.

GreenBus II TM Communication

(Communication Circuit, Low Voltage)

Note: Install cover after GreenBus II TM plugs have been inserted.

Grey

Black

Violet

Black

Dimming Interface (galvanically isolated)

Relay Contact (Line Voltage) switches

for controlling 0-10V electronic dimming

electronic ballasts; recommended relay

ballasts (30mA maximum sinking

switching capacity 347V, 20A maximum

capability).

 

Connect to ENCELIUM Energy Management System only. Do not connect to other circuits.

Maximum 100 total devices

GreenBus IITM must be laid out as per ENCELIUM EMS supplied drawing. If changes are required, determine an optimum wiring path utilizing the supplied prefabricated cables, based on the position of light fixtures and sensors. As the modules obtain power via the GreenBus IITM, the number of modules on each chain is limited. It is suggested to leave room for future system upgrades and to limit the number of modules per chain to 100 units during initial installation.

76-009-DA 11/12

OSRAM and Logo are registered trademarks of OSRAM AG.

ENCELIUM and GreenBus II are trademarks of OSRAM SYLVANIA Inc.

SEE THE WORLD IN A NEW LIGHT is a registered trademark of OSRAM SYLVANIA Inc.

Module Installation

The Area Lighting Controller interface (purple and grey wires) is a galvanically isolated 0-10V circuit such that it may be wired as NEC Class 1 or 2.

In a typical installation, Area Lighting Controller connect to electronic dimming, non-dimming, HID, etc., ballasts to make each individual device controllable by the GreenBus

IITM system. The mechanical construction allows for simpleLuminaire Fixture installation of the module in an available ½-inch knock-out

on top of a fixture, as shown. For some installations, a junction box may be required. It is recommended to securely mount the Area Lighting Controller to the junction box using an available ½-inch knock-out. No retainer nut is needed because the module has integrated retention clips built into the knock-out nipple.

GreenBus IITM communication wiring is still accessible from the outside of the fixture, while all necessary wiring to the electronic dimming ballast is available on the inside.

The module is made from tested material to be used in plenum or “plenum rated” areas. All wiring is rated 600V, 105ºC for use in light fixtures. Wire as shown.

Black wires connect to the internal relay and allow the module to interrupt power to the load for complete shutoff. The purple and grey wires control dimming functions. Refer to local code,

etc.

To control multiple ballasts, parallel all ballast input wires (line, neutral and control wires purple and grey). It is recommended to

observe the maximum ratings of the Area Lighting Controller to ensure maximum ratings are not exceeded (see below).

Recommended Relay switching capacity, 120-347V, 20A maximum.

Recommended Dimming signal capacity, 0-10V, 30mA maximum (sinking).

Due to the internal relay, power feed to fixture may be live even if lights are off. Turn off power at circuit breaker or fuse before installing or servicing module. Observe lockout procedures.

Installation Notes

Various models of the Area Lighting Control are to be installed in dry, indoor locations ONLY. For damp installations, ensure to use the appropriately rated version of the Area Lighting Control Module (see Models section of this manual). Damp locations are defined as: interior locations subject to moderate degrees of moisture, such as some basements, some barns, some cold-storage warehouses, and the like, and partially protected locations under canopies, marquees, roofed open porches, and the like.

Page 2
Image 2
Sylvania 76-009-DA installation manual GreenBus II Wiring, Module Installation, Installation Notes

76-009-DA specifications

Sylvania 76-009-DA is an innovative lighting solution designed to enhance both functionality and aesthetics in various environments. This advanced LED lighting fixture is part of Sylvania's commitment to providing high-quality, energy-efficient products that meet the diverse needs of consumers and businesses alike.

One of the standout features of the Sylvania 76-009-DA is its exceptional energy efficiency. Utilizing LED technology, this light not only consumes significantly less power than traditional incandescent or fluorescent bulbs but also offers a longer lifespan. Users can expect a lifespan of around 25,000 hours, which reduces the frequency of replacements and maintenance costs. This makes it an environmentally friendly choice, minimizing waste while maximizing performance.

The Sylvania 76-009-DA is equipped with adjustable brightness settings, allowing users to customize light levels according to their needs. This feature is particularly beneficial in settings like offices, retail spaces, or homes where different activities might require varying levels of illumination. The ability to dim the lights can create a more inviting atmosphere for gatherings or a focused environment for work.

In terms of design, Sylvania has ensured that the 76-009-DA is both sleek and versatile. Its minimalist design allows it to blend seamlessly into any décor, making it suitable for use in modern homes, luxury apartments, or professional offices. The fixture is available in various color temperatures, from warm white to cool daylight, enabling users to choose the perfect ambiance for their space.

Another significant characteristic of the Sylvania 76-009-DA is its commitment to safety and durability. The fixture is designed with high-quality materials that are resistant to corrosion and heat, ensuring longevity and reliable performance. Additionally, it features built-in safeguards against overvoltage and overheating, providing peace of mind for users.

The installation process for the Sylvania 76-009-DA is straightforward, catering to both DIY enthusiasts and professionals. With its compatibility with standard fixtures, users can easily upgrade their existing lighting without requiring extensive modifications or additional tools.

In summary, the Sylvania 76-009-DA stands out in the world of LED lighting due to its energy efficiency, adjustable brightness, stylish design, and robust safety features. Whether used in commercial or residential settings, this lighting solution delivers on performance, aesthetics, and sustainability, making it a smart choice for modern illumination needs.