1-17

User’s Guide
Technical Specifictions

Table 1-1. Technical Specifications

ITEM DESCRIPTION
Power Requirements*
Wand
RS-232C
Synapse
4.8 (min) to 14.0 VDC (max)
150 mA @ 5V typical
150 mA @ 5V typical
150 mA @ 5V typical
Decode Capability The LS 3603 can be programmed to decode the following
code types: UPC/EAN, Code 39, Code 39 Full ASCII,
Codabar, Interleaved 2 of 5, Code 128, EAN 128,
Discrete 2 of 5, Code 93, and MSI/Plessey. Set code length(s)
for any 2 of 5 code type. The LS 3603 can autodiscri minate
between all of the above code types except for Code 39 and
Code 39 Full ASCII. Transmission of decoded information
will depend on the capabilities of the attached terminal.
Beeper Operation User-selectable: Enabled, Disabled.
Scan Repetition Rate 36 (± 3) scans/sec (bidirection al)
Roll (Skew) Tolerance ± 10° from normal
Pitch ± 50° from normal
Yaw ± 60° from normal
Decode Depth of Field See Decode Zone
Print Contrast Minimum 25% absolute dark/light differential, measured at 675 nm.
Ambient Light Immunity
Artificial Lighting
Sunlight
200 ft. candles 2153 lux
8000 ft. candles 86112 lux
(@8 in. (20 cm) on low density bar
codes)