Image 6

LED behavior

Table 1 describes the behavior of the LEDs.

Table 1: IP GW blade LED behavior

LED

Color

Indicates

Compact Flash Activity

Flashing

 

green

One of:

the IP GW blade is booting

a configuration change has been made

the configuration is being transferred by FTP

Console Link

Green

A PC is connected to the console port

 

 

 

Status

Green

The IP GW blade is operating normally

 

 

 

Alarm

Red

The IP GW blade is booting or has

 

 

developed a fault, for example:

 

 

temperature is outside normal limits

 

 

battery failure of the internal clock

 

 

Refer to the web interface for more

 

 

information about the problem (go to

 

 

Status > Health)

 

 

 

System Load

Green

The IP GW blade is processing data. The

 

 

LEDs represent the media processing load

 

 

of the IP GW blade. The column

 

 

numbered 1 represents audio load. The

 

 

other columns represent video DSP load.

 

 

Media processing load is also displayed in

 

 

the web interface: go to Status > General

 

 

to see the percentage load

 

 

 