1. Introduction
Thank you for purchasing Tannoy B225.
The Tannoy B225 is a 15” direct radiating bass loudspeaker system. For installations that require extended bass response from an
The B225 uses a high efficiency 15” driver, combining powerful, natural bass performance with compact dimensions. M10 flying points located around the cabinet mean the B225 can be quickly and easily installed using the EBS10 Eye Bolt Set.
Capable of delivering high sound pressure levels with extremely low distortion, the B225 adds extra low frequencies with traditional Tannoy reliability.
2. Unpacking
Every Tannoy B225 product is carefully inspected before packing. After unpacking your loudspeakers, please inspect for any exterior physical damage, and save the carton and any relevant packaging materials in case the loudspeaker again requires packing and shipping. In the event that damage has been sustained in transit notify your dealer immediately.
3. Connectors/Cabling
The B225 is fitted with two
The pins of the two Speakon™ sockets, marked input/output on the rear of the input panel, are paralleled within the enclosure.
Tannoy have adopted the following wiring standard for B225:-
SPEAKON™ | SIGNAL |
CONNECTOR |
|
Pin 1+ | Positive |
Pin 1- | Negative |
Should you encounter any problems obtaining Speakon™ connectors, please contact Neutrik or its distributors on the following numbers:-
UK: | NEUTRIK MARKETING: | 01983 811 441 |
USA: | NEUTRIK USA INC.: | +1 732 901 9488 |
For a worldwide list of distributors, please contact Neutrik directly on:-
NEUTRIK AG: | +423 237 2424 |
or visit their website at: http://www.neutrik.com/
Cable choice consists mainly of selecting the correct cross sectional area in relation to the cable length and the load impedance. A small cross sectional area would increase the cables series resistance, inducing power loss and response variations (damping factor).
Connectors should be wired with a minimum of 2.5 sq. mm (12 gauge) cable. This will be perfectly satisfactory under normal conditions. In the case of very long cable runs the wire size should exceed this, refer to the following table for guidance:-
5