18 TASCAM 302MKII

The following messages are displayed on the tape counter when two or more 302MkII units are in use, one serving

as the master machine and the others as the slave machines, and an error is detected :

Problem Possible Cause Solution
Continuous record/play
impossible
REV MODE switch set to Ä or ä. Set switch to CONT.
OFF/SLV/MSTR switch set to SLV or
MSTR. Set switch to the left OFF position.
Poor sound quality
Heads are dirty. Clean them, as stated above.
Inappropriate DOLBY NR switch
setting.
Set switch to the setting used for
original recording.
Heads are magnetized. Demagnetize them, as stated above.
Recording impossible Erase-protection tabs broken off the
cassette. Cover tab holes with plastic tape.

Error Messages

Display Problem Solution
Err2 Commands interrupted somewhere
because of incoherent switch settings
Make settings coherent throughout the
system.
Err3 Incorrect EXT CONTROL connection Correct connection.
Troubleshooting