2 − Names and functions of parts
PARALLEL connector
The PARALLEL connector on the rear panel allows external control of this unit. The pin assignments are as follows.
Pin | Timeline / Take / | Playlist [Dual] | I/O | ||
No. | Playlist [Single] | PonMode | |||
|
| ||||
1 | GND | GND | GND |
| |
2 | PLAY | PLAY A | FLASH 1 | I | |
3 | STOP | STOP A | FLASH 2 | I | |
4 | RECORD | (Reserved) | FLASH 3 | I | |
5 | SKIP FWD | SKIP FWD | FLASH 4 | I | |
6 | SKIP BWD | SKIP BWD | FLASH 5 | I | |
7 | (Reserved) | STOP B | STOP | I | |
8 | FADER_START | FADER_START A | FADER_START | I | |
9 | TALLY_BC_STOP | TALLY_PAUSE B | TALLY_BC_STOP | O | |
| TALLY_PAUSE / |
| TALLY_PAUSE A / |
| |
10 | TALLY_BC_PAUS | TALLY_PAUSE A | TALLY_BC_PAUS | O | |
| E |
| E |
| |
11 | TALLY_RECORD | (Reserved) | RESERVED | O | |
12 | TALLY_STOP | TALLY_STOP A | TALLY_STOP | O | |
13 | TALLY_PLAY | TALLY_PLAY A | TALLY_PLAY | O | |
14 | REMOTE_SELECT | REMOTE_SELECT | REMOTE_SELEC | I | |
, | , | T, L | |||
| H or Open | H or Open |
| ||
|
|
| |||
15 | PAUSE | PAUSE | FLASH 6 | I | |
16 | (Reserved) | PLAY B | FLASH 7 | I | |
17 | AUX1, FF | AUX1, FF | FLASH 8 | I | |
18 | AUX2, REW | AUX2, REW | FLASH 9 | I | |
19 | AUX3, MARK | AUX3, MARK | FLASH 10 | I | |
20 | (Reserved) | A/B SELECT | FLASH_PAGE | I | |
21 | TALLY_BC_STAN | TALLY_PLAY B | TALLY_BC_STAN | O | |
| DBY |
| DBY |
| |
22 | TALLY_BC_CM | TALLY_STOP B | TALLY_CF1 / | O | |
TALLY_BC_CM | |||||
|
|
|
| ||
23 | TALLY_ONLINE | TALLY_ONLINE A | TALLY_ONLINE | O | |
24 | TALLY_BC_END | TALLY_ONLINE B | TALLY_CF2 / | O | |
|
|
| TALLY_BC_END |
| |
25 | +5V | +5V | +5V |
|
I: Command input for transport control Internal circuit, +5V
Operates with low commands of 50 msec or more O:Command output, for tally output
The internal circuit is open collector (10 Ω output impedance)
Low command output when operating
20 V dielectric strength, 35 mA maximum current *+5V: 50 mA maximum supplied current
When REMOTE Select (pin 14) is set to high, it functions according to the operation mode and can be used as an ordinary parallel controller. When set to low, flash start mode is enabled. In addition, depending on the high/low setting of the Flash Page (pin 20), the key assignments are as follows.
Pin 14 | Pin 20 | Flash start take |
Low | High | |
Low | Low |
TALLY_BC_*: Use menu setting to switch output (OFF, ON) (When an
TALLY_BC_STOP/CM/END: | 250 msec pulse output |
TALLY_BC_STANDBY/PAUSE: | Level output |
14 TASCAM
When the main unit’s playlist mode is set to [dual], and REMOTE Select (pin 14) is set to hi, use pin 20 (A/B SELECT) to select player A or B (Hi for player A and Lo for player B).
The following pins affect the selected player. Pin 5 (SKIP FWD)
Pin 6 (SKIP BWD)
Pin 15 (PAUSE)
Pin 17 (AUX1)
Pin 18 (AUX2)
Pin 19 (AUX3)
The following example is of a connection that uses a fader to start and stop playback of this device.
For information about the assignment of AUX
NOTE
When controlling this unit with an external device that is connected to the PARALLEL connector, by simultaneously inputting PLAY and RECORD signals while this unit is stopped, you can start recording immediately. In addition, by simultaneously inputting PLAY and RECORD signals during playback in timeline mode, you can start overwriting the recording.
The
Make settings related to communication on the
NOTE
・
・Please contact TASCAM customer support for information about this unit’s
You can control this unit remotely by connecting the
with SONY P2 protocol
Make settings related to operation on the REMOTE SETUP screen
NOTE
Please contact TASCAM customer support for information about this unit’s protocol compatibility.