22 Models 358 & 359Important: OperatorChecklist
j4. Dispose of o- rings and seals if they are worn,
torn, or fit too loosely, and replace with new
ones.
j5. Follow all lubricat ing procedures as outlined in
“Assembly”.
j6. If your mac hineis air c ooled, check the
condenser for accumulation of dirt and lint.
Dirty condensers will reduce the efficiency
and capacity of the machine. Condensers
should be cleaned monthly with a soft brush.
Never use screwdrivers or other metal
probes to clean between the fins.
Note: For machines equipped with an air
filter, it will be necessary to vacuum clean the
filters on a monthly schedule.
CAUTION: Always disconnect
electrical power prior to cl eaning the
condenser. Failureto follow this
instruction may result in electrocuti on.
Winter StorageIf the place of business is to be closed during the
winter months, it is important to protect the freezer
by following certain precautions, particularly if t he
building is subject to freezing conditions.
Disconnect the freezer from the main power source
to prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Use air pressure to blow out any water
remaining in the condensers. This is extremely
important. Failure to follow this procedure may
cause severe and costly damage to the refrigeration
system.
Your local Taylor Distributor can perform this service
for you.
Wrap detachable parts of the freezer such as
beater, blades, drive shaft, and freezer door. Place
these parts in a protected, dry place. Rubber tr im
parts and gaskets can be protected by wrapping
them with moisture-proof paper. All parts should be
thoroughly cleaned of dried mix or lubrication, which
attract mice and other vermin.