Description

1 - Lens

2 - Probe

3 - Battery compartment

4 - Luminous diodes to show temperature mode : ear or forehead 5 - Screen

6 - Take temperature and memory function button

7 - On/Off and Ear or forehead temperature Mode button 8 - Protection/vertical storage cap.

Precautions for use

This ear and forehead thermometer receives the infra-red rays emitted by the skin’s surface and in the ear drum area. It allows you to check your child’s temperature easily. This is how to use the appliance:

The TEFAL thermometer is exclusively dedicated to take ear or forehead temperatures.

We would like to re-iterate that this appliance does not replace the advice of a doctor. In case of doubt or fever, contact your doctor. TEFAL cannot be held responsible for poor interpretation of results. The simple take of temperature cannot be considered as a medical advice, DO NOT modify the proportion of any drugs prescribed by your doctor without seeking medical advice first.

To ensure the reading is accurate, the probe and the lens must be absolutely clean.

Do not use the thermometer if it has been dropped or shows any signs of damage

Always place the protection cap back after use.

In cases of movement from one room to another, wait for half an hour minimum before using the appliance.

Wait for half an hour after physical training, bathing or eating before measuring temperature.

Keep the thermometer out of reach of children.

Do not expose the thermometer:

-To any warm sources (radiator, sun rays, ...)

-To dust or humidity.

Never immerse the thermometer in liquid.

Do not touch the lens with your fingers.

BODY TEMPERATURE: the normal human body temperature varies during the day. It is measured along a scale of values defined according to the part of the body where the temperature is taken:

-Rectal measurement: 36,6° - 37,8°C

-Axillary measurement (under the arm): 34,7° - 37,3°C

-Oral measurement (in the mouth) or forehead: 35,5° - 37,5°C

-Ear measurement: 35,8° - 37,8°C

Warning, this appliance is not suitable for dectecting hypothermia.

Average temperatures

Forehead

Ear

Rectal

Oral

Axillary

temperature

temperature

temperature

temperature

temperature

36,1°C

36,4°C

37,0°C

36,6°C

36,1°C

Technical specifications

Measurement range

20°C / 42,2°C

 

 

Screen resolution

0,1°C

 

 

Precision

from 32°C to 42°C: +/- 0,2°C

 

< 32°C and > 42°C: +/- 0,3°C

 

 

Operation conditions -

+16°C / +35°C

room temperature

Relative humidity less than 85%

 

 

Storage conditions

- 20°C / +80°C

 

Relative humidity less than 95%

 

 

Energy source

1 lithium battery 3V type CR2032

 

Service life : approximately 5000 measures

 

 

In compliance with the European directive 93/42 (Medical appliances) and EN 12470-5 (medical thermometer).

CE 0120 marking.

Comments: these technical specifications may be subject to modifications to improve the appliance, without prior warning.

Made in China by Hubdic CNS

Imported and distributed by TEFAL SAS

Italia - EC Representative : Bremed Italia S.r.l. Via Alviano 4/1 Gorizia - Italia

TEFAL SAS BP 89 74156 RUMILLY Cedex FRANCE

Before first use

Installing the battery

The appliance is delivered with a lithium battery 3V (CR2032) already in place.

At the first use, open the battery cover then remove the strip which ensures the protection of the battery (fig. 1/fig. 2). Replace the cover (fig. 3).

Functionning

Ear measurement

• Remove the protection cap.

• To switch on press and hold the button

until the indications in fig. 4 are displayed in the

GB

screen the appliance automatically displays the Ear mode. The screen shows the corresponding

 

function fig. 5 and the luminous diode corresponding to the symbol

blink 5 times.

 

Gently pull the ear upwards and backwards to straighten the ear canal. Insert the thermometer into the ear canal fig. 6.

24

25

Page 13
Image 13
Tefal BH1110L0, BH1110J0 manual Precautions for use, Technical specifications, Installing the battery, Ear measurement