Manual ND.qxd 12/01/2005 17:10 Page 18

 

 

Accesories supplied

 

 

1

150/125 mm reduction.

 

1

Anti-recoil valve.

 

2

Support for tubecover.

 

2

Wall supports.

 

4

Screws M4x12.

 

6

Wall plugs (Ø8 x 40).

 

6

Long bolts (Ø5 x 45).

 

4

Wall plugs (Ø6 x 30).

 

4

Long bolts (Ø4 x 30).

 

2

Ø6.4 x Ø18, washers.

 

2

Ø6.4 x Ø12, washers.

 

2

Screws (Ø3.9 x 13).

 

2

Clips.

 

 

 

 

 

 

 

Installation

 

Fig. 1 (Page 19)

ENG

On installing the kitchen hood make sure

that the Safety Instructions set out on page

 

14 are complied with.

To obtain optimum performance, the external duct must not be more than FOUR METRES LONG, have no more than two 90° angles and its diameter must be at least Ø120.

1) Using the attached template, trace and drill the points for fitting the wall plugs onto the wall

(P) (Ø8 x 40) and (J) (Ø6 x 30).

2) Attach the supports (O) to the wall using the long bolts (Q) (Ø 5x45) and the support (H) with the long bolts (I) (Ø 4x30), as in figure 1.

3) Fit the support (O) to the body of the hood using the long bolts (L) (M4 x 12).

4) Trace the location of the wall plugs (R) (Ø8 x 40), through the inside of the kitchen hood.

5) Take the kitchen hood off.

6) Drill into the wall and fit the wall plugs (R) (Ø8 x 40).

7) Hang the kitchen hood; tighten the screws

(M) (M4 x 12) with the washers (A3) (Ø6.4 x Ø12) and the long bolts (S) (Ø5 x 45) with the washers (T) (Ø6.4 x Ø18).

18

8)Adjust the decorative part (U), fixing it softly to the body of the bell using the screws provided with the decorative part.

9)Mount the tubecovers, attaching the lower one to the support (H) as per the detail in figure 1. Lift the upper tubecover up to the desired height and mark its shape on the wall. Remove the tubecovers.

10)Fit the clips (F) to the support (C).

11)Centre the support (C) around the shape marked; trace and drill the fixing points for the wall plugs (E) (Ø6 x 30). Attach the support (C) with the long bolts (D) (Ø4 x 30).

12)Fit the part (A) if the inner tube (not supplied) is Ø150 or (A) + (B) if it is Ø120.

13)Attach the inner tube with a clamp (not supplied) to (A) or (B) as the case may be.

14)Once the inner tube has been fitted, fit the lower tubecover around the extractor fan outlet and attach the upper tubecover with the screws

(G) (Ø3.9 x 13).

15)Adjust the decorative part (U), fixing it tightly to the body of the bell using the screws provided with the decorative part.

When exterior gas extraction is not possible,

Active charcoal filters (Optional)

then the kitchen hood may be set to purify the air by recycling it through active carbon filters.

The active carbon filters have an active life of between three to six months, depending on the individual conditions of use. These filters cannot be washed nor regenerated. They must be replaced once their useful life comes to an end.

SET type 1 - Fig. 3 (Page 19)

1)Put the filters into the lateral draught section of the motor making the holes in the filters match up (A) with the pivots (B) of the motor carcass. Turn as indicated in the diagram.

2)Remove the tubecovers (E). Fit the diffuser

(C) on to the motor's air outlet vent. Fit the tubecovers back on (E).