Installation

To fix the extractor to the kitchen unit the pattern on page 19 is used.

The lower part of the extractor must be located at a minimum height of 60 cm above the hob for electric cookers and 65 cm for gas cookers. If the instruc- tions of a gas cooker indicate a greater distance these must be observed.

The extractor must be connected to a wall socket with an effective earth. When the extractor is working at the same time as other non-electrical cook- ing equipment, the outlet air pressure must not exceed 4 Pa (4 x 10-5 bar).

To achieve optimum performance the length of the outlet hose should not exceed 4 meters, or include more than two 90º angles (elbows)

Although venting to the outside is rec- ommended, activated carbon filters may be used, which allow the gas to be returned to the kitchen through the out- let pipe.

If you wish to exchange the front for one matching the kitchen units, follow the following instructions:

-Withdraw the movable group.

-Remove the screws (T) that support the front

-Install the new front fixing it with the same screws that held the old one.

320

340

Ajuste Prof. Mueble

T

T

T

If something does not work

Before seeking technical assistance car- ry out the following checks first.

Defect

Possible cause

Solution

 

 

 

The extractor

The cable is not connected

Connect the mains cable

does not work

 

 

No current is reaching the plug

Revise/repair the

 

 

electricity circuit

The extractor does not

Filter saturated with grease

Clean or substitute filter

blow enough or vibrates

Outlet obstructed

Eliminate obstructions

 

Inadequate air conduit

Contact the installer and follow

 

 

instructions of this manual

The lamps do not light

Lamp broken

Exchange the bulb

 

Lamp loose

Tighten bulb

 

 

 