Introduction, Features, and Options Teledyne API - Model T200H/T200M Operation Manual
20
1.4. OPTIONS
Option Option
Number Description/Notes Reference
Pumps Pumps meet all typical AC power supply standards while exhibiting same
pneumatic performance.
11A Ship without pump N/A
11B Pumpless Pump Pack N/A
12A Internal Pump 115V @ 60 Hz N/A
12B Internal Pump 220V @ 60 Hz N/A
12C Internal Pump 220V @ 50 Hz N/A
Rack Mount
Kits Options for mounting the analyzer in standard 19” racks
20A Rack mount brackets with 26 in. (660 mm) chassis slides N/A
20B Rack mount brackets with 24 in. (610 mm) chassis slides N/A
21 Rack mount brackets only (compatible with carrying strap, Option 29) N/A
23 Rack mount for external pump pack (no slides) N/A
Carrying Strap/Handle Side-mounted strap for hand-carrying analyzer
29
Extends from “flat” position to accommodate hand for carrying.
Recesses to 9mm (3/8”) dimension for storage.
Can be used with rack mount brackets, Option 21.
Cannot be used with rack mount slides.
N/A
CAUTION – GENERAL SAFETY HAZARD
THE T200H OR T200M ANALYZER WEIGHS ABOUT 18 KG (40 POUNDS).
TO AVOID PERSONAL INJURY WE RECOMMEND THAT TWO PERSONS LIFT AND CARRY THE
ANALYZER. DISCONNECT ALL CABLES AND TUBING FROM THE ANALYZER BEFORE MOVING IT.
Analog Input and USB port Used for connecting external v oltage signals from other instrumentation (such as
meteorological instruments).
64B
Also can be used for logging these signals in the analyzer’s internal
DAS Section 3.4.2
Current Loop Analog
Outputs
Adds isolated, voltage-to-current conversion circuitry to the analyzer’s analog
outputs.
41
Can be configured for any output range between 0 and 20 mA.
May be ordered separately for any of the analog outputs.
Can be installed at the factory or retrofitted in the field.
Section 3.4.5
Parts Kits Spare parts and expendables
42A
Expendables Kit includes a recommended set of expendables for
one year of operation of this instrument including replacement
sample particulate filters.
Appendix B
Calibration Valves Used to control the flow of calibration gases generated from external sources,
rather than manually switching the rear panel pneumatic connections.
50A
AMBIENT ZERO AND AMBIENT SPAN VALVES
Zero Air and Span Gas input supplied at ambient pressure.
Gases controlled by 2 internal valves; SAMPLE/CAL & ZERO/SPAN.
Section 3.5.3.1
50D
ZERO SCRUBBER AND DUAL PRESSURIZED SPAN VALVES
Zero Air Scrubber produces/supplies zero air to the ZERO inlet port.
Dual Pressurized Span Valves for two gas mixtures to separate inlet ports,
HIGH SPAN and LOW SPAN.
Section 3.5.3.2
07270B DCN6512