13.MODEM CONFIGURATION

Telenetics dial and leased line modems are based upon Rockwell chipsets. These chipsets contain Rockwell’s “AT” command set.

A summary of the Rockwell command set for your MIU modem is provided in Book 2.

Unless otherwise specified at the time of order, your modem will have left the Telenetics factory in the configuration detailed on the following pages.

The Telenetics factory configuration differs from the Rockwell default

configuration as follows...

&C0

Rockwell Default

Carrier Detect (CD) always ON.

&C1

Telenetics Factory

Carrier Detect (CD) only ON

 

 

when modem connected (on hook)

S0=0

Rockwell Default

Auto-Answer OFF

S0=1

Telenetics Factory

Auto-Answer on first ring

You can review the configuration of your modem by entering AT&V <CR>.

You can restore the Rockwell factory configuration by entering AT&F&W

MIU Installation, Operation & Diagnostics Edition: January 25, 1999

Page 13