Telenetics 14.4, 2.4, 28.8, 9.6 manual General Product Specifications, Vdc

Models: 14.4 9.6 28.8 2.4

1 31
Download 31 pages 5.12 Kb
Page 7
Image 7

3.GENERAL PRODUCT SPECIFICATIONS

Dimensions:

 

5.3 x 4.0 x 1.375 inches

Weight:

 

1 lb

 

Voltage Supply:

:

8 to 24

VDC

 

 

7 to 16

VAC, 50/60 Hz

 

Optional Wall Transformer

115 VAC, 50/60 Hz

Current Requirements: (See Section 4 for Power Down Modes)

MIU PowerPort 2.4:

 

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

65mA

27mA

7.5mA

6.5mA

5.5mA

MIU PowerPort 9.6:

 

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

115mA

57mA

11mA

10mA

9mA

MIU1 PowerPort 4.4:

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

160mA

69mA

14mA

12mA

9mA

MIU PowerPort 28.8:

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

205mA

125mA

16mA

15mA

11mA

Surge Protection:

Power Supply:

8kVrms

 

 

 

Analog Line:

5kVac (MIU2.4 & 9.6)

 

 

 

3.75kVac (MIU14.4 & 28.8)

 

 

Digital Line:

ESD ± 10kV

 

Operating Temperature:

-40 to +85 deg C

Operating Humidity:

 

0 to 90% (non-condensing.)

Storage Temperature:

 

-55 to 100 deg C

*Note: At temperatures below 0° F, an additional current drain of up to 350 ma occurs as the internal proportional heater operates.

MIU Installation, Operation & Diagnostics Edition: January 25, 1999

Page 5

Page 7
Image 7
Telenetics 14.4, 2.4, 28.8, 9.6 manual General Product Specifications, Vdc