Circuit Board Configuration Jumpers

To change the jumper settings, remove the top cover.

J6: Call Light Configuration

Jumper on pins 1-2: Light flashes during call (default-typical setting).

Jumper on pins 2-3: Light stays lit during call.

J8: Relay Configuration

Jumper on pins 1-2: Normal Open (NO) contacts closed continuously during call (default-typical setting).

Jumper on pins 2-3: Relay contacts toggle at flash rate during call.

Installation

1.Plug the supplied PS-L Power Supply into an AC wall outlet and into the 12-15 VDC power jack on the back of the CIA-1000.

2.Set the System Select switch to the "in" position for Audiocom or the "out" position for RTS TW.

3.Set the Channel Select switch:

Audiocom, the position of the switch does not matter.

RTS TW intercom system: select either channel 1 or channel 2 as desired.

4.Connect the CIA-1000 to an intercom channel like any other intercom station.

External Switch

Normally, the CIA-1000 indicator light and relay are actuated by call signals on the intercom channel. The CIA-1000 may also be modified to actuate the light and relay using an external, user-supplied switch. See Figure for location of the switch connector.

Mounting

The CIA-1000 can be wall mounted using the slotted holes in the bottom of the case.

The front-light version can be installed in an equipment rack using optional Audiocom rack mounts.

J5: EXTERNAL SWITCH

J6: CALL LIGHT OPERATION

On continuously during call

Flash during call

RMK-S Single-Unit Rack Mount Kit for one 1/2-rack wide Audiocom component*

RMK-D Dual-Unit Rack Mount Kit for two 1/2-rack wide Audiocom components*

Audiocom Rack Mount Kits

J8: RELAY OPERATION

Toggle during call

On continuously during call

602

Location of Jumpers and External Switch Connector

2

Page 2
Image 2
Telex CIA-1000 specifications Circuit Board Configuration Jumpers, Installation, External Switch, Mounting