REAR PANEL
POWER AMP OUTPUT CONNECTORS
Power amp output connection for the two channels A (left) and B (right) is provided via
A plastic cover to prevent inadvertent erroneous connection protects the BRIDGED OUT connector. Make sure to remove the cover only when actually operating the power amplifier in
BRIDGED MODE
With the
The regular output voltage of each amplifier channel A / B is still present at the corresponding output connector CHANNEL A or CHANNEL B. However, us- ing these signals is not recommendable because of the aforementioned phase inversion. Operating the power amp in Bridged Mode with loads of 2ohms con- nected is not allowable.
CAUTION: Extremely high voltages might be present at the BRIDGED OUT connector during
GROUND-LIFT SWITCH
The
MAINS INPUT
Under normal circumstances, the mains fuse only blows in case of fault. Replacing the fuse is only permissible when using a new fuse of the same
type with identical amperage, voltage and blow characteristics. If the mains fuse blows more often, please contact an authorized service centre.
The
to the mains, if possible. Using mains cords with smaller diameters results in higher leakage and conse- quently reduced maximum power output capacity.
At 100V and 120V units the mains fuse is installed internally. This is fore safety reasons. In case of a blown mains fuse please contact a qualified service personnel for servicing.
8