MAINS OPERATION & RESULTING TEMPERATURE

MAINS OPERATION & RESULTING TEMPERATURE

The following tables allow determining power supply and cabling requirements.

The power drawn from the mains network is converted into output power to feed the connected loudspeaker systems and into heat. The difference between power consumption and dispensed power is called power dissipation (Pd). The amount of heat resulting from power dissipation might remain inside of a rack-shelf and needs to be diverted using appropriate measures. The following table is meant as auxiliary means for calculating temperatures inside of a rack-shelf system/cabinet and the ventilation efforts necessary.

The column „Pd“ lists the leakage power in relation to different operational states. The column „BTU/hr“ lists the dispensed heat amount per hour.

CP 1200

Umains

Imains

Pmains

 

Pout

Pd (5)

BTU/hr(1)

 

[V]

[A]

[W]

 

[W]

[W]

 

idle

230V

0,37

42

 

-

42

143

Max. Output Power @ 8(1)

230V

4,6

743

 

2 x 240

263

895

Max. Output Power @ 4(1)

230V

7,5

1310

 

2 x 400

510

1740

1/3 Max. Output Power @ 4(1)

230V

4,7

774

 

2 x 133

508

1735

1/8 Max. Output Power @ 4(1)

230V

3,2

496

 

2 x 50

396

1350

1/8 Max. Output Power @ 4(2)

230V

3,0

460

 

2 x 50

360

1230

1/8 Max. Output Power @ 4(2),(4)

254V

3,4

600

 

2 x 63

426

1455

Normal Mode (-10dB) @ 4(1)

230V

3,0

450

 

2 x 40

370

1260

Rated Output Power (0dB) @ 4(1)

230V

6,6

1152

 

2 x 300

552

1885

Alert (Alarm) Mode (-3dB) @ 4(1)

230V

5,0

828

 

2 x150

528

1800

Max. Output Power @ 2(1)

230V

11,6

2210

 

2 x 600

1010

3445

1/8 Max. Output Power @ 2(1)

230V

5,0

820

 

2 x 75

670

2285

1/8 Max. Output Power @ 2(2)

230V

4.7

755

 

2 x 75

605

2065

(1) Sine Modulation (1kHz)

(2) VDE-Noise

 

(3) 1BTU = 1055.06J = 1055.06Ws

(4) 10% Mains Over Voltage

(5) Pd = Leakage Power

 

 

 

 

The following factors allow direct proportional calculation of the mains current Imain for different mains supply voltages: 100V = 2.3; 120V = 1.9; 240V = 0.96