The following tables allow determining power supply and cabling requirements.
The power drawn from the mains network is converted into output power to feed the connected loudspeaker systems and into heat. The difference between power consumption and dispensed power is called power dissipation (Pd). The amount of heat resulting from power dissipation might remain inside of a
The column „Pd“ lists the leakage power in relation to different operational states. The column „BTU/hr“ lists the dispensed heat amount per hour.
CP 1200 | Umains | Imains | Pmains |
| Pout | Pd (5) | BTU/hr(1) |
| [V] | [A] | [W] |
| [W] | [W] |
|
idle | 230V | 0,37 | 42 |
| - | 42 | 143 |
Max. Output Power @ 8Ω(1) | 230V | 4,6 | 743 |
| 2 x 240 | 263 | 895 |
Max. Output Power @ 4Ω(1) | 230V | 7,5 | 1310 |
| 2 x 400 | 510 | 1740 |
1/3 Max. Output Power @ 4Ω(1) | 230V | 4,7 | 774 |
| 2 x 133 | 508 | 1735 |
1/8 Max. Output Power @ 4Ω(1) | 230V | 3,2 | 496 |
| 2 x 50 | 396 | 1350 |
1/8 Max. Output Power @ 4Ω(2) | 230V | 3,0 | 460 |
| 2 x 50 | 360 | 1230 |
1/8 Max. Output Power @ 4Ω(2),(4) | 254V | 3,4 | 600 |
| 2 x 63 | 426 | 1455 |
Normal Mode | 230V | 3,0 | 450 |
| 2 x 40 | 370 | 1260 |
Rated Output Power (0dB) @ 4Ω(1) | 230V | 6,6 | 1152 |
| 2 x 300 | 552 | 1885 |
Alert (Alarm) Mode | 230V | 5,0 | 828 |
| 2 x150 | 528 | 1800 |
Max. Output Power @ 2Ω(1) | 230V | 11,6 | 2210 |
| 2 x 600 | 1010 | 3445 |
1/8 Max. Output Power @ 2Ω(1) | 230V | 5,0 | 820 |
| 2 x 75 | 670 | 2285 |
1/8 Max. Output Power @ 2Ω(2) | 230V | 4.7 | 755 |
| 2 x 75 | 605 | 2065 |
(1) Sine Modulation (1kHz) | (2) |
| (3) 1BTU = 1055.06J = 1055.06Ws | ||||
(4) 10% Mains Over Voltage | (5) Pd = Leakage Power |
|
|
|
|
The following factors allow direct proportional calculation of the mains current Imain for different mains supply voltages: 100V = 2.3; 120V = 1.9; 240V = 0.96