Telex MCE325 manual Test and Adjustment Procedures, Cleaning, Test Equipment, Power Supply Test

Models: MCE325

1 85
Download 85 pages 25.05 Kb
Page 40
Image 40
Cleaning

2The ribbon connector from the front panel board to the main board is attached at both ends with locking connectors. To unlock the connector, pull the outer shell away from the circuit board. Then, pull the ribbon cable out.

Cleaning

Clean the front panel and case with alcohol or a mild solution of detergent and water, and then wipe off detergent residue with a damp rag. Clean the circuit board (if necessary) with a tetraflouroethane product such as Flux-Off® CZ by Chemtronics®. Use eye protection and avoid breathing the vapors with these solvents. Also, avoid getting the solvent in any of the potentiometers.

Test and Adjustment Procedures

Notes

All AC voltages are RMS unless otherwise specified.

All input and output levels were measured using an AC voltmeter calibrated for 1 mW = 0.775V at 600 ohms, but with the 600 ohms in the circuit (0 dBu).

The following procedures involve changing the MCE325 programming. It may be useful to note the current positions of all jumpers and DIP switches so that they can be returned to their proper positions after testing.

The inside of the top cover contains a location diagram for the programming jumpers and DIP switches. Place it next to the MCE325 during testing for convenient reference.

Test procedures are written to be performed in the order presented.

Test Equipment

Variac

15 MHz Oscilloscope

AC Voltmeter

Frequency Counter

DC Voltmeter

Balanced Audio Generator

400 Hz to 30 kHz bandpass filter with +40 dB of gain

Power Supply Test

1Set a variac to 117 VAC, 60 Hz, and connect the MCE325 to the variac. Observe that each LED blinks on in sequence, and then all LED’s are off.

2Measure the voltage across the secondary of T1 (between test points E7 and E8 on the main circuit board).

Vsec = 18 ±1.8 VAC

3Measure the DC voltage across the “+” and “-“ terminals of bridge rectifier CR1. VCR1 = 23 ±2.3 VDC

4-2C S I - 2 0 0 U s e r I n s t r u c t i o n s

Page 40
Image 40
Telex MCE325 manual Test and Adjustment Procedures, Cleaning, Test Equipment, Power Supply Test