TYPICAL 1-CHANNEL CABLE WIRING

3

Pair 1

3

2

2

 

1

Pair 2

1 (Both wires)

Shield

 

Shield

Cable Type: 22AWG Stranded, 2-Pair Twisted-wire, with Shield

Connector Type: 3-Pin XLR Audio (Neutrik or Switchcraft)*

Pin 1: Common

Denotes twisted pair.

Pin 2: Channel Audio / Power

 

Pin 3: Channel Audio / Power

Denotes shield.

Shield: Earth ground

 

TYPICAL 2-CHANNEL CABLE WIRING

4

 

Pair 1

 

4

3

 

 

3

 

 

 

6

 

Pair 2

 

6

5

 

 

5

 

 

 

1

 

Pair 3

 

1 (Both wires)

Shield

 

 

 

Shield

Cable Type: 22AWG Stranded, 3-Pair Twisted-wire, with Shield

Connector Type: 6-Pin XLR Audio (Neutrik only, not compatible with 6-pin Switchcraft)*

Pin 1: Channel 1 & 2 Common

 

 

Pin 2: No connection

 

 

Denotes twisted pair.

Pin 3: Channel 1 Audio / Power

 

Pin 4: Channel 1 Audio / Power

 

Denotes shield.

Pin 5: Channel 2 Audio / Power

 

Pin 6: Channel 2 Audio / Power

 

 

Shield: Earth ground

 

 

 

 

3

“Y” CABLE WIRING

Ch1

2

 

 

4

 

1

 

Pair 1

Case

 

3

 

 

 

 

 

Pair 2

6

 

 

 

5

 

3

 

 

 

 

Pair 3

1 (Both wires)

Ch2

2

 

 

1

 

 

Shield

Shield

 

 

Use second drain wire if available, or add an extra section of wire.

*Standard cables are generally constructed using a male connector at one end and a female connector at the other end. This allows several cables to be interconnected to create longer cable runs. Audiocom master stations, speaker stations and belt packs also typically provide both a male and female Neutrik connector for each intercom channel. This permits loop-through connection of several intercom stations using the standard cables. Audiocom power supplies use a 3-pin male Neutrik connector for each channel. Audiocom wallplates use male Neutrik connectors.

Figure 3 - Cable Wiring Diagrams for Audiocom Applications.