3-4. 120-240 50/60 Hz VAC CHARGER AND AC TO DC CONVERTER LIMITS
The unit is designed with a single point AC receptacle for external
power to operate both the internal charger and converter. The unit’s
AC voltage range can be factory set from 105 to 250 VAC at 50 to 60 Hz
depending upon customer requirements. The AC power cord provided with
the unit is the mechanism that ensures the specified AC power source
is properly supplied to the unit (see paragraph 3-5). Use no others.
INTERNAL CHARGER: NO LIMIT AC power cord can remain connected when
power cells are fully charged. When the power cells are fully
charged the unit’s intelligent charger will go to a stand-by mode,
LED will stay green or flicker, monitor the power cells state of
charge and only charge the power cells to ensure they stay at maxi-
mum capacity.
INTERNAL AC TO DC CONVERTER: LIMITED (see paragraph 3-6, 3-8 and 3-
10). AC power cord does not have to be disconnected when converter
power output is no longer required. Once DC power demand is termi-
nated the unit’s intelligent charger will remain on line to ensure
power cells are charged to maximum capacity.
CAUTION
*8$5’)520 ,1&255(&7
32:(56285&( Unit will be damaged if unapproved AC power is applied.
3-5 AC POWER CORD LIMITS
The AC power cord governs which AC power source the unit is set to
operate from. The TI4676 is supplied with a single customer specified
AC power cord. Some customers may specify a non North American AC
option (for worldwide mobility see appendix A). Each power cord is
marked accordingly.
FOR MORE INFORMATION ON POWER CORDS SEE APPENDIX A
3-2