www.ti.com

ABSOLUTE MAXIMUM RATINGS

DISSIPATION RATING TABLE

RECOMMENDED OPERATING CONDITIONS

TPA3008D2

SLOS435A – MAY 2004 – REVISED JULY 2004

These devices have limited built-in ESD protection. The leads should be shorted together or the deviceplaced in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates.

over operating free-air temperature range (unless otherwise noted)
(1)
TPA3008D2
Supply voltage range AV
CC
, PV
CC
-0.3 V to 20 V
Load Impedance, R
L
6
SHUTDOWN -0.3 V to VCC + 0.3 VInput voltage range, V
I
GAIN0, GAIN1, RINN, RINP, LINN, LINP -0.3 V to 6 V
Continuous total power dissipation See Dissipation Rating Table
Operating free–air temperature range, T
A
- 40°C to 85°C
Operating junction temperature range, T
J
- 40°C to 150°C
Storage temperature range, T
stg
- 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratingsonly, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operatingconditions” is not implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability.
DERATINGPACKAGE T
A
25°Cθ
JC
FACTOR T
A
= 70°C T
A
= 85°C(1/θ
JA
)
PHP 4.3 W 1.14 °C/W
(1)
34.7 mW/°C
(1)
2.7 W 2.2 W
(1) Based on a JEDEC high-K PCB with the PowerPAD™ soldered to a thermal land on theprinted-circuit board. See the PowerPAD Thermally Enhanced Package application note (SLMA002).The PowerPAD must be soldered to the PCB.
T
A
= 25°C (unless otherwise noted)
MIN MAX UNIT
Supply voltage, V
CC
PV
CC
, AV
CC
8.5 18 V
High-level input voltage, V
IH
SHUTDOWN, GAIN0, GAIN1 2 V
Low-level input voltage, V
IL
SHUTDOWN, GAIN0, GAIN1 0.8 V
SHUTDOWN, V
I
= V
CC
= 18 V 10 µAHigh-level input current, I
IH
GAIN0, GAIN1, V
I
= 5.5 V, V
CC
= 18 V 1 µA
SHUTDOWN, V
I
= 0 V, V
CC
= 18 V 1 µALow-level input current, I
IL
GAIN0, GAIN1, V
I
= 5.5 V, V
CC
= 18 V 1 µA
High-level output voltage, V
OH
FAULT, I
OH
= 100 µA AV
DD
- 0.8 V V
Low-level output voltage, V
OL
FAULT, I
OL
= -100 µA AGND + 0.8 V V
Frequency is set by selection of ROSC and COSCOscillator frequency, f
OSC
200 300 kHz(see the Application Information Section).
Operating free–air temperature, T
A
-40 85 °C
2