Table of Contents
Introduction | 1 | ||
1. | Specifications | 2 | |
2. | Operation | 2 | |
| 2.1 | Transporting | 2 |
| 2.2 | Electrical Requirements | 2 |
| 2.3 | Condensate Removal | 2 |
| 2.4 | Ducting | 2 |
| 2.5 | Power Switch | 3 |
| 2.6 | Pump Purge Switch | 3 |
| 2.7 | Hour Meter | 3 |
| 2.8 | Temperature Specific Operation | 3 |
| 2.9 | Low Pressure Control | 4 |
3. | Maintenance | 4 | |
| 3.1 | Air Filter | 4 |
| 3.2 | Storage | 4 |
4. | Service | 4 | |
| 4.1 | Technical description | 5 |
| 4.2 | Troubleshooting | 5 |
| 4.3 | Blower Replacement | 6 |
| 4.4 | Defrost Thermostat and Timer | 6 |
| 4.5 | Condensate Pump | 6 |
| 4.6 | Gravity Drain Option | 6 |
| 4.7 | Relay | 7 |
5. | Options and Accessories | 7 | |
6. | Wiring Diagram | 7 | |
7. | Service Parts | 8 | |
8. | Warranty | 9 |
Serial No. ___________________________
Purchase Date ______/______/_____
Dealer’s Name ___________________________________
Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix 200 HT dehumidifier.
•It is designed to be used INDOORS ONLY.
•If used in a wet area, plug it into a GROUND FAULT IN-
TERRUPTER.
•DO NOT use the Phoenix 200 HT as a bench or table.
•It must always be used in the upright position.
1 Specifications
Part No. | 4025900 |
Power | 7.5 amps, |
Water | 140 pints/day @ AHAM (80°F, 60%) |
Removal | 26 pints/day @ saturation |
| 32 gal/day maximum @ saturation |
Blower | 325 CFM without external ducting |
| 310 CFM @ .15 IWG external static |
Operating | 33°F min., 125°F max. |
Range |
|
Refrigerant | 1 lbs., 14 oz. |
Charge |
|
Filters 16” x 20” x 2” Pleated Media
Duct Options Intake – 12”
Supply – 10”
Warranty | Five years; |
|
| st year 100% of Parts and Labor | |
| ||
| refrigeration system. | |
Dimensions |
|
|
| Machine | Shipping |
Width | 20.25” | 24” |
Height | 40” | 45.25” |
Depth | 21.375” | 25.5” |
Weight | 138 lb | 164 lb |
2 Operation
2.1 Transporting
The Phoenix 200 HT must always be upright when transported by vehicle. It may be tipped onto its handle and back for loading and moving by hand. The Phoenix
200 HT features a
2.2 Electrical Requirements
The Phoenix 200 HT plugs into a common grounded outlet on a 15 Amp circuit. It draws 7.5 Amps at 80°F, 60% RH. If used in a wet area, a ground fault interrupter (GFI) is required. If an extension cord is required, it must have a minimum of 14 gauge conductors if 25 feet long or less and 12 gauge conductors if greater than 25 feet long.
www.thermastor.com • sales@thermastor.com |