Therma-Tru®Light Commercial/Multi-Family - Doors and Frames

 

Material shown on these drawings will be

 

 

fabricated only after formal approval by the

 

 

architect, receipt of approval hardware schedule,

 

 

and all necessary hardware templates.

 

• All frames shall be shipped “knocked-down”

 

 

unless otherwise specified.

 

• All frames and doors shall be chemically washed,

 

 

rinsed, and dried prior to receiving one coat of

 

 

paint.

NOTES

Doors and frames will be reinforced for surface

 

mounted hardware as required. Drilling and

 

tapping for surface mounted hardware shall be

 

 

applied by others.

DOOR HANDING CHART

SINGLE DOORS

OUTSIDE

 

 

 

OUTSIDE

 

 

 

 

 

LEFT HAND INSWING

 

 

 

RIGHT HAND INSWING

 

 

 

 

 

 

 

 

 

OUTSIDE

OUTSIDE

LEFT HAND REVERSE/

RIGHT HAND REVERSE/

RIGHT HAND OUTSWING

LEFT HAND OUTSWING

PAIRS OF DOORS

All standard type hardware will be located at this

 

manufacturer’s standard locations as shown on

 

the door and frame elevations. Hardware items

 

such as panic exit devices, deadbolts, etc. will also

 

be located at manufacturer’s standard locations

 

unless specifically advised.

Installations of all glass and glazing to be

 

performed by others.

Doors, frames, and finished hardware to be

 

installed by others.

Anchor bolts and expansion shields for any type

 

fastener to be furnished by others.

GENERAL

It will be the responsibility of the General

 

Contractor to coordinate hardware locations.

 

 

 

All frames will be supplied with the required wall

 

 

and floor anchors as illustrated on the frame detail

 

 

sheet.

 

• All frames and doors wll be tagged with shop

 

 

marks. This schedule can be used to cross

OUTSIDE

LEFT HAND ACTIVE

OUTSIDE

LEFT HAND REVERSE ACTIVE/

RIGHT HAND OUTSWING ACTIVE

OUTSIDE

RIGHT HAND ACTIVE

OUTSIDE

RIGHT HAND REVERSE ACTIVE/ LEFT HAND OUTSWING ACTIVE

• All frames must be set absolutely plumb, square,

and level.

• All frames will be supplied with rubber door silencers: three for single swing openings and two per header for double swing openings.

 

reference shop marks with architects marks.

These drawings are not intended for use by other

 

trades.

Field welding, grinding, finishing, and attachment

 

of field splices by others.

JOB NUMBER:

PROJECT:

LOCATION:

ARCHITECT:

CONTRACTOR:

FINISHED HARDWARE BY:

SHEET NUMBER:

OF

RECORD OF SUBMITTALS

SUBMITTEDRETURNED

1st

2nd

3rd

4th

RECORDED APPROVED DRAWINGS

RECORDED APPROVED HARDWARE

DRAWN BY: