Thermador PHREM Use and Care, Installation, Equipment Needed Drill and Bit Screwdriver, Over

Models: PHREM

1 8
Download 8 pages 44.81 Kb
Page 2
Image 2
Use and Care

The Thermador Pro Hood Remote Control is designed for use in applications where the controls on the hood are not accessible. The remote control can be installed on any vertical surface. It is most often installed in the kitchen backsplash or just above the backsplash in the back wall. The Pro Hood Remote Control is compatible with Pro Hood model numbers ending in 03 or higher. The model number is printed on the serial label on the back wall of the hood.

Use and Care

Refer to “Operating the Hood” in the Pro Hood Care and Use Manual for operating instructions.

The remote control can be wiped clean with a damp cloth. Be careful not to use excessive water as it could damage the controls. Refer to the Care and Use Manual included with your Pro Hood for more detailed instructions.

Installation

Equipment Needed: Drill and Bit Screwdriver

Keyhole saw (or equivalent depending on installation surface)

Rubber Mallet

Equipment Included:

Remote Control

Extension Cable

Anchors (2)

Screws (2)

Installation Instructions

Screw Covers (4)

1.Disconnect power at breaker.

2.Attach the hood in the desired location using either the ceiling (island hoods only), wall or cabinet installa-

Remote Connection;

Connect Extension Cable

Here

Power Supply Box;

Disconnect Control

Harness and Connect

Remote Harness Here

tion method described in the Pro Hood Installation Instructions (included with the hood).

Before installing duct covers and integral blower or connecting wiring, install the remote control as described below.

3.Prepare Hood for Installation.

WALL OR CABINET MOUNT HOODS:

Remove 3 screws from the front edge of the light panel and set aside. Support panel while removing.

Behind light panel, disconnect halogen lights at

plastic wire connectors and heat lamps (if applicable) at flag connectors (one yellow and one white

for each lamp).

Set light panel aside.

CEILING MOUNT ISLAND HOODS:

Remove 1 screw from channel run cover. Set panel and screw aside.

Remove 5 screws from front filter tray. Set tray and screws aside.

Remove 3 screws from control panel cover. Set panel and screws aside.

(Over)

Remote Connection;

Connect Extension Cable

Here

Power Supply Box;

Disconnect Control

Harness and Connect

Remote Harness Here

Figure 1: Pro Hood with Light Panel Removed

Figure 2: Pro Island Hood with Panels Removed

Page 2
Image 2
Thermador PHREM manual Use and Care, Installation, Equipment Needed Drill and Bit Screwdriver, Equipment Included, Over