Thermador PHREM Disconnect control harness from black power supply box, Turn on power at breaker

Models: PHREM

1 8
Download 8 pages 44.81 Kb
Page 3
Image 3
4.Disconnect control harness from black power supply box.

4.Disconnect control harness from black power supply box.

5.Connect remote harness to power supply (See Figure 1). The remote harness is attached to the hood near the black power supply box.

Reconnect halogen lights and heat lamps and reinstall light panel (wall or cabinet mount hood only).

Install integral blower (if applicable) and connect hood wiring as described in Pro Hood Installation Instruc- tions (wall or cabinet mount hood only).

6.Connect remote control extension cable to remote connection. See figures 1 and 2 (previous page) for location.

Remove duct covers if previously installed.

7.Route cable to desired remote control location.

Complete Hood Installation as described in the Pro Hood Installation Instructions.

8.Make installation cut-out in desired location.

Drill starter holes for screws (2). See Figure 3 for appropriate dimensions.

Caution: Take care not to contact electrical wires or damage other objects behind wall.

9.Place anchors (provided) in starter holes.

10.Connect extension cable to remote control at 10 pin connector (if not already connected)

11.Place remote control in installation hole.

12.Install 2 screws (provided). Use rubber mallet to install screw covers (provided) over screw heads.

13.Turn on power at breaker.

14.Test for proper operation.

3/8”

3/8”

3/16” dia.

3

 

 

1

 

 

1/2”

11 1/4”

 

 

Figure 3: Remote Control Installation Cut-out Dimensions

We reserve the right to change specifications or design without notice. Some models are certified for use in Canada. Thermador is not responsible for products which are transported from the U.S. for use in Canada. Check with your local Canadian distributor or dealer.

For the most up to date critical dimensions by fax, use your fax handset and call 775-833-3600. Use code # 8030.