System Will Not Operate

1) Plugged into dead outlet

1)

Plug into live grounded outlet

 

2)

Blown fuse or breaker

2)

Replace fuse or breaker

 

3)

Defective power cord

3)

Replace power cord

 

4)

Defective switch

4)

Replace switch

 

5)

Loose wiring

5)

Properly connect wiring

 

6)

Improper connection

6)

Press tightly into outlet

 

 

 

 

Vacuum Motor Will Not Run

1) Main power not activated

1)

Active main power switch

 

2)

Loose wiring

2) Tighten and connect wiring

 

3)

Defective vacuum switch

3)

Replace vacuum switch

 

4)

Defective vacuum motor

4)

Replace vacuum motor

 

 

 

 

Pump Will Not Run

1) Main power not activated

1)

Activate main power

 

2)

Defective pump switch

2)

Replace pump switch

 

3)

Loose wiring

3) Tighten and connect wiring

 

4)

Plugged spray jet

4)

Remove blockage

 

5)

Lint buildup in hose coupling

5)

Disassemble and remove lint

 

6)

Kink in solution hose

6)

Straighten hose

 

7)

Defective pump

7)

Replace pump

 

 

 

 

Pump Runs But Will Not

1) Solution tank empty

1)

Refill solution tank

Spray/Weak Spray

2) Obstructed spray jet

2)

Remove blockage

 

3)

Obstructed hose coupling

3)

Remove obstruction

 

4)

Obstructed solution filter

4)

Clean filter

 

5)

Hose damage

5)

Replace necessary hose

 

6)

Pump components

6)

Replace pump

 

 

wearing out

 

 

 

 

 

 

Loss of Vacuum Suction

1) Recovery dome not seated

1)

Re-seat for better seal

 

2)

Obstruction in vac hose

2)

Remove obstruction

 

3)

Obstruction in wand

3)

Remove obstruction

 

4)

Screen filter clogged

4)

Remove debris

 

5)

Recovery dome needs gasket

5)

Replace dome gasket

 

 

 

 

 