![](/images/new-backgrounds/1074172/7417225x1.webp)
Troubleshooting
Condition |
| Cause |
| Correction |
|
|
|
|
|
System Will Not Operate | 1) Plugged into dead outlet | 1) | Plug into live grounded outlet | |
| 2) | Blown fuse or breaker | 2) | Replace fuse or breaker |
| 3) | Defective power cord | 3) | Replace power cord |
| 4) | Defective switch | 4) | Replace switch |
| 5) | Loose wiring | 5) | Properly connect wiring |
| 6) | Improper connection | 6) | Press tightly into outlet |
|
|
|
| |
Vacuum Motor Will Not Run | 1) Main power not activated | 1) | Active main power switch | |
| 2) | Loose wiring | 2) Tighten and connect wiring | |
| 3) | Defective vacuum switch | 3) | Replace vacuum switch |
| 4) | Defective vacuum motor | 4) | Replace vacuum motor |
|
|
|
| |
Pump Will Not Run | 1) Main power not activated | 1) | Activate main power | |
| 2) | Defective pump switch | 2) | Replace pump switch |
| 3) | Loose wiring | 3) Tighten and connect wiring | |
| 4) | Plugged spray jet | 4) | Remove blockage |
| 5) | Lint buildup in hose coupling | 5) | Disassemble and remove lint |
| 6) | Kink in solution hose | 6) | Straighten hose |
| 7) | Defective pump | 7) | Replace pump |
|
|
|
| |
Pump Runs But Will Not | 1) Solution tank empty | 1) | Refill solution tank | |
Spray/Weak Spray | 2) Obstructed spray jet | 2) | Remove blockage | |
| 3) | Obstructed hose coupling | 3) | Remove obstruction |
| 4) | Obstructed solution filter | 4) | Clean filter |
| 5) | Hose damage | 5) | Replace necessary hose |
| 6) | Pump components | 6) | Replace pump |
|
| wearing out |
|
|
|
|
|
| |
Loss of Vacuum Suction | 1) Recovery dome not seated | 1) | ||
| 2) | Obstruction in vac hose | 2) | Remove obstruction |
| 3) | Obstruction in wand | 3) | Remove obstruction |
| 4) | Screen filter clogged | 4) | Remove debris |
| 5) | Recovery dome needs gasket | 5) | Replace dome gasket |
|
|
|
|
|
12