All installations and services must be performed by qualified service personnel.
A. VENTING:
NOTE: On the OH6FA072D*** it is possible to rotate the flue elbow (which is factory installed for vertical discharge) 90° counterclockwise from the vertical position to adapt to various venting systems.
cCAUTION MUST BE TAKEN NOT TO EXCEED 90° ROTATION (OF THE FLUE ELBOW) COUNTERCLOCKWISE OR RIGHT FROM THE VERTICAL POSITION.
ROTATION OF FRONT FLUE ELBOW
When an installation requires that the flue exit out the left hand side casing on a front flue unit, remove screw securing the 90 deg. elbow and rotate it 90° counterclockwise. Then, remove
A trim collar may be ordered from Thermo Products to hide the gap around the flue pipe. This trim collar, however, is not required for operation. Trim collar/gasket part numbers(s) 14121 / 330073.
NOTE: ROTATION OF FLUE PIPE IS ONLY ALLOWED FOR LEFT HAND SIDE VENTING APPLICATIONS.
The OH6FA072D*** may be vented through a standard correctly sized chimney.
The OH6FA072D*** may also be horizontally vented through a side wall. Thermo Products has available the Field model
SIDE WALL VENTING APPLICATION ORDER INFORMATION
| FIELD VENT | SIDE WALL VENT | COMBUSTION AIR |
| TERMINATION KIT | ACCESSORIES KIT | INTAKE HOOD KIT |
| (15’ application MAX) | (BURNER SPECIFIC) | (FOR COMBUSTION AIR |
| THERMO PRODUCTS | THERMO PRODUCTS | APPLICATIONS ONLY) |
| THERMO PRODUCTS | ||
BURNER | PART NUMBER | PART NUMBER | PART NUMBER |
Beckett AFG | AOPS8393 | AOPS8394 | AOPS8396 |
|
|
|
|
Riello BF3 | AOPS8393 | AOPS8395 | AOPS8396 |
|
|
|
|
The Field vent kit is set up with 4 inch diameter vent pipe with concentric
The side wall vent may be installed either through the upper
The combustion air inlet can be installed through the either the lower left side casing
2