Toro 69X-06-XX, 69X-02-XX Connecting Electric Control Wires, Wire Sizing Chart, System Start-Up

Models: 69X-01-XX 69X-02-XX 69X-06-XX

1 12
Download 12 pages 32.93 Kb
Page 3
Image 3
Connecting Electric Control Wires

Connecting Electric Control Wires

Table 1 - Wire Sizing Chart

1.Route control wires to sprinkler location(s). Provide enough extra wire at sprinkler to allow for movement of sprinkler without straining wire connections. One common wire and one station

wire are required for each sprinkler. See Wire Sizing Chart, Table 1 for proper application.

2.Attach control wires to solenoid leads using an approved waterproof splicing method.

CAUTION

All wires must be waterproofed to prevent short circuit to ground and subsequent controller damage.

Connecting Hydraulic Control Tubing

1.Route control tubing from controller to sprinkler location(s).

Note: Leave an 18 inch service loop of tubing at each sprinkler to facilitate movement of sprinkler and service operations. Tubing runs in excess of 1,000 feet are not advisable due to delayed response time. The controller for hydraulic valve-in-head systems should never be located more than 25 feet below or more than 70 feet higher than the valves. Although there is no limit to the amount of hydraulic valve-in- head sprinklers controlled by one control station, practical experience suggests the maximum number of heads normally used is five.

2.Flush tubing thoroughly to remove all air and debris.

3.Remove tube retainer and poly cap from tubing adapter at base of sprinkler.

Maximum Allowable Length in Feet From Controller to VIH Sprinklers.

VOLTAGE

 

WIRE SIZE

 

 

 

NUMBER OF VALVES

 

 

 

AT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROLLER

CONTROL

 

COMMON

 

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110 VAC

 

14

 

 

14

 

2348

1012

 

549

353

 

 

 

 

 

 

 

 

 

 

 

 

 

110 VAC

 

14

 

 

12

 

2890

1239

673

433

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110 VAC

 

14

 

 

10

 

3378

1448

 

786

505

 

 

 

 

 

 

 

 

 

 

 

 

 

110 VAC

 

12

 

 

12

 

3759

1604

873

561

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110 VAC

 

12

 

 

10

 

4591

1973

1071

 

688

 

 

 

 

 

 

 

 

 

 

 

 

 

110 VAC

 

12

 

 

8

 

5411

2328

1263

812

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110 VAC

 

10

 

 

10

 

5945

2555

1387

892

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC

 

14

 

 

14

 

2765

1309

846

549

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC

 

14

 

 

12

 

3393

1608

1039

673

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC

 

14

 

 

10

 

3962

1877

1213

783

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC

 

12

 

 

12

 

4394

2082

1346

872

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC

 

12

 

 

10

 

5397

2557 1652

1071

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC

 

12

 

 

8

 

6364

3018

1949

1263

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC

 

10

 

 

10

6986

3311

2140

1387

 

 

 

 

 

 

 

 

 

 

 

Chart based on the following:

Transformer

- 115 VAC - 124 VAC, 45 VA

 

 

 

 

 

 

 

 

 

Coil Assy.

- 24 VAC, 60 Hz

 

 

 

 

 

 

 

 

Holding

 

-

.21 Amps

 

 

 

 

 

 

 

 

 

In Rush

 

-

.42 Amps

 

 

 

 

4.Slide tube retainer over control tubing and attach tubing to adapter. Slide tube retainer over adapter area to secure tubing.

System Start-Up

The following is a recommended procedure that will protect system components during system start-up. The procedure is based on a velocity fill rate of less than 2 feet per second. See Table 2 below.

1. Use jockey pump only to fill system at velocity fill rate of less than 2 feet per second.

WARNING

TO PREVENT PERSONAL INJURY, DO NOT STAND DIRECTLY OVER ANY COMMERCIAL OR LARGE TURF HEAD DURING FILL OR WHEN ACTIVATING MANUALLY AT THE HEAD.

2.Use quick coupler keys at all tees and greens with quick coupler valves to bleed air from system lines during filling process. Do not compress air and then relieve - bleed air while filling system.

3.After water has filled all lines and all air is removed, remove quick coupler keys.

CAUTION

Failure to comply with recommended fill rate will increase line pressure resulting in a water hammer effect that could damage sprinklers.

Table 2

 

 

 

 

 

 

 

 

Pipe Size

Gallons Per

Velocity - Feet

Pipe Size

Gallons Per

Velocity - Feet

 

 

 

 

 

 

Inches

Minute

Per Second

Inches

Minute

Per Second

 

 

 

1/2

2

1.60

 

3

45

1.86

 

 

3/4

3

1.92

 

4

75

1.87

 

 

1

5

1.50

 

6

150

1.73

 

 

1-1/4

10

1.86

 

8

250

1.70

 

 

1-1/2

10

1.41

 

10

450

1.97

 

 

2

20

1.80

 

12

500

1.55

 

 

2-1/2

30

1.84

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Page 3
Image 3
Toro 69X-06-XX Connecting Electric Control Wires, Wire Sizing Chart, Connecting Hydraulic Control Tubing, System Start-Up