SERVICE MODE LIST

This unit provided with the following SERVICE MODES so you can repair, examine and adjust easily. To enter the Service Mode, press both set key and remote control key for more than 2 seconds.

Set Key

 

Remocon Key

Operations

 

VOL. (-) MIN

 

0

Reset the user setting items (PICTURE, VOLUME and LANGUAGE) to the initial state

 

 

 

for delivery.

 

 

 

 

 

 

 

 

 

 

Initialization of the factory.

 

 

 

 

 

 

VOL. (-) MIN

 

1

NOTE: Do not use this for the normal servicing.

 

 

If you set a factory initialization, the memories are reset such as the

 

 

 

 

 

 

channel setting, and the POWER ON total hours.

 

 

 

 

 

 

 

 

 

 

POWER ON total hours is displayed on the screen.

 

 

 

 

 

 

VOL. (-) MIN

 

6

Refer to the "CONFIRMATION OF HOURS USED".

 

 

 

Can be checked of the INITIAL DATA of MEMORY IC.

 

 

 

 

 

 

 

Refer to the "WHEN REPLACING EEPROM (MEMORY) IC".

 

 

 

 

 

 

 

VOL. (-) MIN

 

8

Writing of EEPROM initial data.

 

 

NOTE: Do not use this for the normal servicing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOL. (-) MIN

 

9

Display of the Adjustment MENU on the screen.

 

 

 

Refer to the "ELECTRICAL ADJUSTMENT" (On-Screen Display Adjustment).

 

 

 

 

 

 

 

 

 

 

CONFIRMATION OF HOURS USED

POWER ON total hours can be checked on the screen. Total hours are displayed in 16 system of notation.

NOTE: If you set a factory initialization, the total hours is reset to "0".

1. Set the VOLUME to minimum.

ADDRESS DATA

 

2.Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.

3. After the confirmation of using hours, turn off the power.

INIT 01

00

 

 

 

CRT ON

0010

FIG. 1

Initial setting content of MEMORY IC. POWER ON total hours.

=(16 x 16 x 16 x thousands digit value) + (16 x 16 x hundreds digit value)

+ (16 x tens digit value) + (ones digit value)

C-1

Page 12
Image 12