FIELD REPLACEABLE UNIT DOCUMENTATION

TM

Satellite

1900 Series

15” DISPLAY MASK REMOVAL

Latch

Display mask

LCD

LCD/FL harness cover

Mask seals

1.Slide the LCD/FL harness cover to the left and lift it out.

2.Remove two mask seals at the bottom corners of the display assembly using a pair of fine-tipped tweezers.

2.Remove two M2.5x7 flat head black screws securing the display mask.

3.There are 23 latches securing the display mask. Carefully insert your fingers between the mask and the LCD panel and pry open the latches starting from the bottom six latches, to the five latches on the right and left sides, ending with the six top latches.

FL INVERTER AND 15” LCD REMOVAL

LCD module

 

M2x3

M2x3

black

screws

black

 

screws

 

FL cable

LCD/FL cable

M2x5 silver screw

FL inverter board

1.Remove two M2x5 silver screw securing the FL inverter board.

2.Carefully lift up the FL inverter board and disconnect the LCD/FL cable from CN1 and the FL cable from CN2.

3.Remove four M2X3 black screws securing the LCD module.

5.Carefully rotate out the top of the LCD module enough to access the display cable

6.Peel off the tape securing the LCD/FL cable and disconnect the cable.

6.Remove eight M2x3 black screws securing the left and right LCD brackets and separate the brackets.

TOSHIBA

Tough Enough for Today’s World

Page 12
Image 12
Toshiba 1900 Series manual Remove two M2x5 silver screw securing the FL inverter board