Toshiba HVR16-X, EVR8-X, EVR32-X, HVR32-X, HVR8-X, EVR16-X Alarm Setup, Configure Sensor Response

Models: EVR32-X HVR16-X EVR16-X EVR8-X HVR8-X HVR32-X

1 135
Download 135 pages 56.28 Kb
Page 64
Image 64
ALARM SETUP

46

ALARM SETUP

The Alarm window allows you to enable, disable and configure Sensors and Control Outputs.

Create & Name Sensor Presets

Open On-Screen Keyboard

Configure Hybrid (IP) Sensors*

Normally Open (NO) /Configure Sensor Response

Normally Closed (NC)

Delay Triggering Relay Output

Assign

Relays

 

comma delineated

*Requires the HVR Software Upgrade

Configure Sensor Response

1.Click the Setup button on the Main Display Screen.

2.Click the Alarm Setup button to open the Alarm display.

3.Click the NO or NC check box to select Normally Open or Normally Closed for the desired sensor.

4.Enter the Delay Time to define the number of seconds after the sensor is tripped until the relay is activated.

5.Enter the relay(s) to associate with the sensor. Two or more relays can be associated with a single sensor – separate with commas.

6.Click Apply.