(b)Changing the automatic shutter detection (ratio between peak and average value) Move the “ ” to PEAK/AVE by pressing [MENU UP], [MENU DOWN] buttons.

Select the ratio between peak and average value by presshing [DATA UP], [DATA DOWN] buttons.

(Peak:Average)

The peak value increases by pressing [DATA UP]

00:10 05:05 10:00

The peak value decreases by pressing [DATA DOWN]

(c) Changing the automatic shutter response speed

Move the “ ” to SPEED by pressing [MENU UP], [MENU DOWN] buttons.

Select the response speed by presshing [DATA UP], [DATA DOWN] buttons.

The response speed becomes faster by pressing [DATA UP]

1 10 20

The response speed becomes slower by pressing [DATA DOWN]

(d) Changing the automatic shutter zone area

Move the “ ” to AREA by pressing [MENU UP], [MENU DOWN] buttons.

Select the measurement light area by pressing [DATA UP], [DATA DOWN] buttons.

DATA UP

PRESET A PRESET B PRESET C PRESET D PRESET E

DATA DOWN

The available picture area is shown by the shading correction on the screen that is parted in 64.

PRESET A

PRESET B

PRESET C

PRESET D

PRESET E

Note:

These picture areas are not displayed on the screen.

16